80S-20用户手册.pdf - 第392页

7 What should you do ... SIPLACE 80S-20 /F4 User Manual 7.13 Line engineer profile Software version SR.407.xx 01/2001 US Edition 392 7.13 Li ne eng ineer pro file The line en gineers sh ould norma lly have attended the S…

100%1 / 570
SIPLACE 80S-20/F4 User Manual 7 What should you do ...
Software version SR.407.xx 01/2001 US Edition 7.12 Operator profile
391
7.12 Operator profile
The operating personnel are to be assigned the following tasks:
Supplying the feeder module with sufficient components
Checking to make sure that the right components are placed in the feeder modules
Promptly refilling the components and splicing the tapes
Checking to make sure that the components are in their correct pick-up positions (see
Fig. 7.9 - 1
)
Checking the flow of material to the PCBs on the input and output conveyor
Checking the quality of the PCBs
Random sampling of the PCBs before they enter the soldering furnace.
Observing the EGB regulations
Avoiding errors (see sections 7.7.1
).
Noting error displays and messages on the station and notifying the line engineer, if necessary
Carrying out the maintenance work specified in the User Manual
7 What should you do ... SIPLACE 80S-20/F4 User Manual
7.13 Line engineer profile Software version SR.407.xx 01/2001 US Edition
392
7.13 Line engineer profile
The line engineers should normally have attended the SIPLACE basic training course and are to
be assigned the following tasks:
Acting as a contact for the operators
Maintaining the machine log book
Monitoring and carrying out maintenance at the specified intervals
Monitoring the workplace to ensure that it is clean and safe
Monitoring conformity with EGB regulations
Carrying out quality control
Following up and reporting fault messages
Making sure that errors have been eliminated
Providing all materials required to produce the job in a timely manner, such as
PCBs
Soldering paste
Components
Feeder modules, etc.
Setting up the station for a new production batch
Checking the settings of the feeder modules
Checking the management data
Asking the responsible programmers to modify placement programs
Ensuring a smooth flow of information between the individual groups
7
SIPLACE 80S-20/F4 User Manual 8 Error information and diagnostics
Software version SR.407.xx 01/2001 US Edition 8.1 General
393
8 Error information and diagnostics
8.1 General
If errors occur during operations at the placement station, you can all up information concerning
the possible causes and ways of eliminating the error in question. To do this, you start the help
system for the station computer (see Chapter 9
).
You call error information on the currently displayed error by clicking the "Error information"
button in the main view (see section 8.2.1
).
You can call up information on an observed error of a specific type by clicking the "Error infor-
mation" button in the corresponding error display (see section 8.2.2
).