12 Station extensions / software SIPLACE 80S-20 /F4 User Manual 12.2 GEM interface Software version SR.407.xx 01/2001 US Edition 538 Possible setti ngs: 12 Connect at power -up 12 (See also secti on 12.2.2.5 ) 12 – Ye s …

100%1 / 570
SIPLACE 80S-20/F4 User Manual 12 Station extensions / software
Software version SR.407.xx 01/2001 US Edition 12.2 GEM interface
537
SIPLACE Pro 12
When a cluster is specified at the station, all the data required for this are loaded from the com-
puter specified in the configuration of the SIPLACE Pro connection. The data must be located on
the hard disk of this computer. 12
12
Å Select the button for the required control mode.
Å Click OK to confirm and activate this setting.
12.2.2.2 Defining the GEM default settings
You use the "GEM default settings..." menu option to make various settings which will be used at
power-up as default parameters for the station. 12
Å In the main view select the Options menu and then select the option GEM default settings....
The following window is displayed.
12
Fig. 12.2 - 2 "GEM-Defaults" window
12 Station extensions / software SIPLACE 80S-20/F4 User Manual
12.2 GEM interface Software version SR.407.xx 01/2001 US Edition
538
Possible settings: 12
Connect at power-up 12
(See also section 12.2.2.5) 12
Yes
When the station is switched on, the station computer attempts to connect to the host com-
puter.
No
When the station is switched on, no connection to the host computer is made. However, the
operator can establish the connection manually in the "State view" (see also section 12.2.2.5
).
Control 12
(See also section 12.2.2.5) 12
Off-line
It is not possible to send or receive messages.
Local
In the "Placement Program" view, the user can "upload" placement programs from the station
computer to the host computer (See also section 12.2.2.6
).
No placement programs can be downloaded from the host computer to the station computer.
Remote
In the "Placement Program" view, the user can upload placement programs from the station
computer to the host computer and "download" from the host computer to the station computer.
Spooling 12
(See also section 12.2.2.5) 12
Yes
If the connection to the host computer is lost, the station will collect in a spooling file all mes-
sages intended for the host computer. Once the connection is re-established, the host can pick
up these messages from the station. The quantity of messages which can be stored is limited
by the size of the spooling file (20 MB).
No
If the connection to the host computer is lost, all messages intended for the host computer will
be lost.
SIPLACE 80S-20/F4 User Manual 12 Station extensions / software
Software version SR.407.xx 01/2001 US Edition 12.2 GEM interface
539
Spool full action 12
Overwrite
If there is no more space available in the spooling file, the oldest, stored message is overwritten
by the latest, current message.
Ignore message
If there is no more space available in the spooling file, all new incoming messages will be dis-
carded
Limit monitoring
Not currently relevant.
12
Å Click the Accept button to save the settings.
Å Click the SECS Parameters... button if you want to modify the SECS parameters (see also
section 12.2.2.3
).