80S-20用户手册.pdf - 第523页
SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware Software vers ion SR.407.xx 0 1/2001 US Edit ion 11. 10 PCB data transfer 523 1 1.10.2 Activating t he PCB dat a transf er option Å Clic k on the ‘ Machine op…

11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.10 PCB data transfer Software version SR.407.xx 01/2001 US Edition
522
11.10 PCB data transfer
11.10.1 Functional description
The ‘PCB data transfer’ option has been included in the ‘Machine options’ menu. The aim of this
function is to increase the line performance of your placement system by fully measuring a PCB
at the first placement machine, determining the associated fiducial, subpanel, ink spot, etc, data,
saving this data and then sending it to the next machine. At the next machine, it is then only nec-
essary to determine the data for two fiducial positions. These two fiducial positions are then used
to correct the position of each subsequent machine for the PCB to be placed. It is thus not neces-
sary to measure the entire PCB, together with its subpanels, ink dots, etc. 11
Fig. 11.10 - 1 Machine option: PCB data transfer
PLEASE NOTE: The PCB data transfer function can only be used if a PCB barcode reader is in-
stalled. 11
SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.10 PCB data transfer
523
11.10.2 Activating the PCB data transfer option
Å Click on the ‘Machine options’ button from the main view.
The ‘Machine options’ window will appear.
Å Select the ‘PCB data transfer’ option from the ‘Options’ box at the machine concerned.
Å Click on the ‘Accept’ button. The ‘PCB data transfer’ option is now active.

11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.11 Feeder position recognition Software version SR.407.xx 01/2001 US Edition
524
11.11 Feeder position recognition
11.11.1 General
A feeder can be measured if it is equipped with position fiducials. 11
This function can also be used with the waffle tray holder (manual tray) if it has position fiducials. 11
If the ‘Feeder position recognition’ function is selected on the line computer, this function will ap-
pear in the machine options. 11
You can then activate or deactivate feeder position recognition at each station from the machine
options. 11
.
Fig. 11.11 - 1 Feeder position recognition
PLEASE NOTE:
The ‘feeder position recognition’ function is always inactive when the station is switched on. 11