80S-20用户手册.pdf - 第288页
6 Vision functions SIPLA CE 80S-20/F4 User Manual 6.6 Test Co mponent Software version SR.407.xx 01/2001 US Edition 288 6.6.3.2 Load GF data Option NOTE 6 When you call t he Load GF dat a opt ion, fi rst of all t he Save…

SIPLACE 80S-20/F4 User Manual 6 Vision functions
Software version SR.407.xx 01/2001 US Edition 6.6 Test Component
287
6.6.3.1 Camera Type Option
NOTE 6
The buttons for selecting the different camera types can only be used with the F
machines.
6
Fig. 6.6 - 11 Select package form menu, Camera type option
Å Select the camera type if the component is to be centered with another camera type, in addition
to the default camera.
6

6 Vision functions SIPLACE 80S-20/F4 User Manual
6.6 Test Component Software version SR.407.xx 01/2001 US Edition
288
6.6.3.2 Load GF data Option
NOTE 6
When you call the Load GF data option, first of all the Save GF data box will drop down, pro-
vided that you have already processed a package form (see Fig. 6.6 - 10).
Fig. 6.6 - 12 Select package form menu, Load GF data package
If you wish to save your data, the package form file will be transmitted to the line computer. Fol-
lowing this inquiry the component which has just been processed will be rejected and the package
form number list updated. 6
Å From the list field use the mouse pointer to select a particular package form. The selected
package form will appear against a cyan-colored bar.
Å Click on the Load GF data button. In the Package form display field the package form and the
package form will be displayed.
The station computer will request the package form data of the selected package form from the
line computer. The interpreter edits the data and generates the teaching command. With this com-
mand the edited package form data is loaded into the MVS system (vision analysis unit). 6

SIPLACE 80S-20/F4 User Manual 6 Vision functions
Software version SR.407.xx 01/2001 US Edition 6.6 Test Component
289
6.6.3.3 Save GF data Option
Using this option you can save package forms together with their changed parameters. The button
will only be active after you have modified the package form data. 6
6
Fig. 6.6 - 13 Select package form menu, Save GF data option