80S-20用户手册.pdf - 第552页

13 Software installation SIPLACE 80S-20/F4 User Manual 13.2 Installation of the 407.x x station software Software version SR.407.xx 01/2001 US Edition 552 13.1.3 Upgrade The installati on of a software vers ion with a hi…

100%1 / 570
SIPLACE 80S-20/F4 User Manual 13 Software installation
Software version SR.407.xx 01/2001 US Edition 13.1 General definitions
551
13 Software installation
13.1 General definitions
13.1.1 Initial installation
This is the term used to describe the first time the station software is installed on the computer
system of the 6,3/$&(6)
. During this installation, sample machine data is installed on
the station computers hard disk in addition to the individual "SC" (station computer) and "MC"
(machine controller) software components. 13
13.1.2 Update
If an initial installation has already been performed and a more recent release of the station
software has to be installed, this is known as an "update". When an update is performed, the
stored machine data is not overwritten!
The release is identified by the last two digits of the software version designation.
Example
SR.407.01 SR = system component 407 = version number 01 = release
(station computer)
NOTE
Software versions with recent releases are debugged versions.
They are NOT functionally different from software versions with older releases and are generally
compatible with them.
13 Software installation SIPLACE 80S-20/F4 User Manual
13.2 Installation of the 407.xx station software Software version SR.407.xx 01/2001 US Edition
552
13.1.3 Upgrade
The installation of a software version with a higher version number than an already installed
software version is known as an "upgrade".
When an upgrade is performed, the machine data is retained and automatically converted to the
new data format if necessary.
The functionality of the station software is identified by the three-digit number (version number)
of the complete software version designation.
Example
SR.407.xx 407 = version number This identifies the functionality of the software.
13.2 Installation of the 407.xx station software
For the procedure for the installation of the station software, please refer to the software version
description for the corresponding version. 13
NOTE
The software version description is supplied with the software package for the station software.13
13
13.3 Installation of the software for "Remote Service"
(option)
For the procedure for the installation of the "ReachOut" software which is used for the "Remote
Service", please refer to the software version description for the corresponding version. 13
NOTE
The software version description is supplied with the software package for the "ReachOut"
software. 13
13
SIPLACE 80S-20/F4 User Manual Index
01/2001 US Edition
553
Index
Numerics
12 mm S module for capacitors based
on powdered metal, model C/D
. . . . . . . . .430
12 mm S module for capacitors based
on powdered metal, model E
. . . . . . . . . . .431
12/16 mm S module
. . . . . . . . . . . . . . . . . . . . .429
12-segment Collect&Place head
. .35, 38, 39, 212,
214
angular accuracy
. . . . . . . . . . . . . . . . . 35, 39
component illumination control board
. . . . .214
component vision module
. . . . . . . . . . 57, 213
component vision system
. . . . . . . . . . . . . .229
description
. . . . . . . . . . . . . . . . . . . . . . . . . .58
gantry 1
. . . . . . . . . . . . . . . . . . . . . . . . . . .211
gantry 2
. . . . . . . . . . . . . . . . . . . . . . . . . . .211
motor for "Reject" valve adjustment drive
. . .57
placement accuracy
. . . . . . . . . . . . . . . 35, 39
star motor
. . . . . . . . . . . . . . . . . . . . . . . . . . .57
star with 12 sleeves
. . . . . . . . . . . . . . . . . . .57
structure
. . . . . . . . . . . . . . . . . . . . . . . . . . . .57
technical data
. . . . . . . . . . . . . . . . . . . . 58, 61
turning station
. . . . . . . . . . . . . . . . . . . . . . . .57
with component vision module
. . . . . . . . . . .36
with component vision module (gantry 1)
. . .33
with component vision module (gantry 2)
. . .33
Z axis driving mechanism
. . . . . . . . . . . . . . .57
1-D pattern search
. . . . . . . . . . . . . . . . . . . . . .222
24/32 mm S module
. . . . . . . . . . . . . . . . . . . . .432
24x24 component camera
. . . . . . . . . . . . . . . .214
24x24 component vision module
technical data
. . . . . . . . . . . . . . . . . . . . . . .229
2-D pattern search
. . . . . . . . . . . . . . . . . . . . . .222
3 x 8 mm S module
. . . . . . . . . . . . . . . . . . . . . .428
44 mm S module (80F4)
. . . . . . . . . . . . . . . . . .435
56 mm S module (80F4)
. . . . . . . . . . . . . . . . . .436
72 mm S module (80F4)
. . . . . . . . . . . . . . . . . .437
8 mm S II module
. . . . . . . . . . . . . . . . . . . . . . .427
88 mm S module (80F4)
. . . . . . . . . . . . . . . . . .438
A
Abort processing
. . . . . . . . . . . . . . . . . . . . . . . .132
Acceptable barcodes
. . . . . . . . . . . . . . . . . . . .153
Access level
. . . . . . . . . . . . . . . . . . . . . . . . . . .140
Action window
. . . . . . . . . . . . . . . . . . . . . . . . . 406
Actuate clamping
. . . . . . . . . . . . . . . . . . . . . . . 206
Actuate DP-axis
. . . . . . . . . . . . . . . . . . . . . . . 182
Actuate stopper
. . . . . . . . . . . . . . . . . . . . . . . . 206
Add button
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 513
Additional data security measures
. . . . . . . . . 532
Additional information
. . . . . . . . . . . . . . . . . . . 397
adequately trained
. . . . . . . . . . . . . . . . . . . . . . . 67
Adjusting the conveyor width
. . . . . . . . . . . . . 209
adjustment structure
. . . . . . . . . . . . . . . . . . . . 488
affected employees
. . . . . . . . . . . . . . . . . . . . . 112
ambient factors, permissible
. . . . . . . . . . . . . . . 43
analysis of the fiducial shapes
. . . . . . . . . . . . 227
angular position
. . . . . . . . . . . . . . . . . . . . . . . . 299
approximate position of the component
. . . . . 299
asynchronous transport type
. . . . . . . . . . . . . . 476
description
. . . . . . . . . . . . . . . . . . . . . . . . 476
function
. . . . . . . . . . . . . . . . . . . . . . . . . . . 476
atmospheric humidity
. . . . . . . . . . . . . . . . . . . . 43
authorized employees
. . . . . . . . . . . . . . . . . . . 112
automatic rinsing after
. . . . . . . . . . . . . . . . . . . 517
automatic selection of
measuring parameters
. . . . . . . . . . . . . . . 338
automatic selection of
suitable measuring modes
. . . . . . . . . . . . 338
automatic setting of the lighting
. . . . . . . . . . . . 338
B
Ball
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298, 324
analysis
. . . . . . . . . . . . . . . . . . . . . . . . . . . 335
measurement
. . . . . . . . . . . . . . . . . . . . . . 335
Ball image option
. . . . . . . . . . . . . . . . . . . . . . . 315
ball imaging parameters
. . . . . . . . . . . . . . . . . 310
Ball measuring mode
. . . . . . . . . . . . . . . . . . . 334
Ball mode
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
Barcode comparison, display
. . . . . . . . . . . . . 154
Barcodes do not match
. . . . . . . . . . . . . . . . . . 153
Barcodes match
. . . . . . . . . . . . . . . . . . . . . . . 153
bare dies
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
brightness value
. . . . . . . . . . . . . . . . . . . . . . . 312
brush with retainer
. . . . . . . . . . . . . . . . . . . . . . 517
brushing / rinsing tank
. . . . . . . . . . . . . . . . . . . 517
bulk case feeder (80F4)
. . . . . . . . . . . . . . . . . 434
buttons
. . . . . . . . . . . . . . . . . . . . . . 241, 275, 317