11 Station extensions /Hardware SIPLACE 80S-20 /F4 User Manual 11.9 Flux dispenser unit Software version S R.407.xx 01/2001 US Edition 516 1 1.9.7.3 Editing the flux p arameters Å Select th e “ Parameters ” menu to e nte…

SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.9 Flux dispenser unit
515
11
Fig. 11.9 - 8 Editing the fluxing package form list
(1) Highlight the line
(2) ‘Edit’ button
(3) Input boxes
11
Å Edit the data as described for Add.
Å Click on OK to confirm your input.
Å Click on Accept to save the edited package form list.
11
311 111 211

11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.9 Flux dispenser unit Software version SR.407.xx 01/2001 US Edition
516
11.9.7.3 Editing the flux parameters
Å Select the “Parameters” menu to enter data for the fluxing process.
11
Fig. 11.9 - 9 Editing the flux parameters
11
Waiting time for the PCB conveyor 11
– The time for which the PCB remains in the station until it undergoes further placement. This
ensures that the flux dries reliably, and the component cannot “float away”.
– This time is measured from the last flip-chip component to be placed,
– and can be set to between 0 and 40 seconds.
PLEASE NOTE
Setting this waiting time can have a detrimental effect on line utilization. 11
11

SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.9 Flux dispenser unit
517
11
Fig. 11.9 - 10 Rinsing / brushing station with rinsing tank
(1) Brush with retainer
(2) Rinsing / brushing station
(3) Brushing / rinsing tank
11
11
Automatic rinsing after: 11
– To prevent the centering nozzle and dispensing needle from crystallizing after a long break
between flux applications, a time can be set after which the rinse cycle starts. This means
that the preset rinse cycle is carried out immediately before the next flip-chip is placed, ac-
cording on the selected placement sequence.
– A rinse cycle is carried out automatically when the machine is switched on, regardless of
the set rinsing time.