80S-20用户手册.pdf - 第372页

7 What should you do ... SIPLACE 80S-20 /F4 User Manual 7.2 Switching off the SIPLACE line Software version SR.407.xx 01/2001 US Edition 372 7.2.3 St arting stations that remain switched on after the li ne compu ter has …

100%1 / 570
SIPLACE 80S-20/F4 User Manual 7 What should you do ...
Software version SR.407.xx 01/2001 US Edition 7.2 Switching off the SIPLACE line
371
7.2.2 Switching off the stations
ATTENTION
NEVER switch off the station during operation using just the main switch except in an emergency.
Shut down the operating system of the station with "Shut down computer..." before you switch off
the station. If you switch off the station during operation without properly shutting down the oper-
ating system beforehand, then the station computer may not start up the next time the station is
switched on. 7
7
Proceed as follows to switch off the station: 7
Å Terminate all placement operations.
Å Check to make sure that the z-axes of all placement heads are in the upper end position.
Å Check to see if there are still components in the placement heads and remove any components
found.
Å If necessary, move all gantries to the standby position with the help of the corresponding gantry
functions (see chapter 5
, section 5.2.3.1).
NOTE
All gantries are normally moved to the standby position automatically. 7
Å Click on the menu function Shut down computer... in the Mode menu.
All station computer processes are terminated. After the operating system has shut down, a
message will appear on the screen stating that the computer can now be switched off.
Å Now switch off the station on the main switch.
7 What should you do ... SIPLACE 80S-20/F4 User Manual
7.2 Switching off the SIPLACE line Software version SR.407.xx 01/2001 US Edition
372
7.2.3 Starting stations that remain switched on after the line computer has been
shut down
If stations remain switched on after the line computer has been shut down and the line computer
is then restarted, the computer will not automatically establish connections with those stations.
The following error messages may appear on the line computer monitor: 7
No correct connection between line computer and station
The line computer was shut down and restarted, so the station must also be shut down and
restarted.
7
There are two ways of re-establishing the connection between the line computer and station after
the line computer has been shut down: 7
1st option 7
Å Disable the conveyor interface at the stations from the Machine options menu.
Å Run all the PCB feeders on the line until they are empty.
Å Switch the stations off and on again.
The stations will establish connections with the line computer.
Å Press the Start button when prompted. The reference point run will then be carried out.
Å Continue placement.
2nd option 7
Å Select the Line engineer access level (password required) from the Options menu.
Å Select the Stand-alone option from the Operating mode menu.
The PCB conveyor for the station will run on until empty.
Å Wait until you are prompted to press the Start button.
Å Select Line computer from the Operating mode option in the Options menu.
The station will automatically establish a connection with the line computer.
Å Press the Start button.
The reference point run will then be carried out.
Å Set the access level back to Operator.
Å Continue placement.
SIPLACE 80S-20/F4 User Manual 7 What should you do ...
Software version SR.407.xx 01/2001 US Edition 7.3 Changing jobs
373
7.3 Changing jobs
Å Interrupt the job defined for the station on the line computer using the function (Interrupt).
Å Enter the new job on the line computer using the function (Schedule).
Å Check the width of the conveyor belt.
Å Check the position of the magnetic supports and make sure that they cannot collide with com-
ponents on the bottom of the PCB.
Å Carry out the set-up check.
Make sure that the feeder modules are equipped with the correct components and that the
feeder modules are at the correct locations.
Å Check the nozzle configuration in the nozzle changer.
If no nozzle changer is installed, then you must change the nozzles manually.
NOTE
If you change the nozzle manually, ALWAYS make sure that you are using the correct nozzle
type and that the nozzle is seated correctly on the spindle. (The plunger pin must click into
place in the notch slot of the nozzle).
If you have not inserted a nozzle or have used the wrong nozzle type, then the station com-
puter program will prompt you to move the placement head to the service position and
change the nozzle. This error message will also appear if you have not inserted the nozzle
correctly.
If you insert the wrong nozzle or use the wrong nozzle type again, then the gantry will move to
the service position once more after the reference sequence. The station computer program
will continue to prompt for a nozzle change until you have obtained the correct configuration.
If you do not succeed, then proceed as follows:
Å Switch off the station and cancel the specified job on the line computer.
Å Rectify the nozzle error and restart the station.