SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.10 PCB data transfer
523
11.10.2 Activating the PCB data transfer option
Å Click on the Machine options button from the main view.
The Machine options window will appear.
Å Select the PCB data transfer option from the Options box at the machine concerned.
Å Click on the Accept button. The PCB data transfer option is now active.
11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.11 Feeder position recognition Software version SR.407.xx 01/2001 US Edition
524
11.11 Feeder position recognition
11.11.1 General
A feeder can be measured if it is equipped with position fiducials. 11
This function can also be used with the waffle tray holder (manual tray) if it has position fiducials. 11
If the Feeder position recognition function is selected on the line computer, this function will ap-
pear in the machine options. 11
You can then activate or deactivate feeder position recognition at each station from the machine
options. 11
.
Fig. 11.11 - 1 Feeder position recognition
PLEASE NOTE:
The feeder position recognition function is always inactive when the station is switched on. 11
SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.11 Feeder position recognition
525
If the cluster data contains an entry for a track, the PCB camera on the feeder moves to the posi-
tion of the centering fiducial. Any centering fiducial offset determined by measurement is allocated
to this track, and added to the pick-up position during the pick-up process. 11
11.11.1.1 Restrictions
Feeder position recognition cannot be used for WPC trays that are set up in the wafflepack
changer.
Up to three fiducial positions can be defined for each feeder.
Feeder fiducials on the right-hand side of the table (viewed in the transport direction) cannot
be measured on the 80F.
PLEASE NOTE:
This restriction does not apply to machines with a sub-gantry camera. 11
If there is a feeder at location 118, and the fiducial position of the outer pick-up division is closer
to the X-axis travel range limit than the pick-up position, then the 8 mm S tape and bulk case
feeder cannot be scanned.