The rinse cycle is carried out via the rinsing station, in a rinsing tank provided for this pur-
pose (see Fig. 11.9 - 10
).
The time can be set to between 0 and 600 minutes.
Number of rinse cycles: 11
If you have set a time for automatic rinsing, then you can also set the number of rinse cy-
cles.
This can be set to between 1 and 10 rinse cycles.
11
Automatic brushing after 11
A time can be set for activating the brushing cycle, in order to clean the centering nozzle
and dispensing needle. During this cycle, the fluxer head moves over the rinsing tank to
which a brush is attached.
A brushing cycle is carried out automatically when the machine is switched on, regardless
of the set brushing time.
The brushing cycle is carried out via the rinsing station, in the rinsing tank provided.
(see Fig. 11.9 - 10
).
The time can be set to between 0 and 120 minutes.
11
Number of brushing cycles 11
If you have set a time for automatic brushing, then you can also set the number of brushing
cycles.
This can be set to between 1 and 10 brushing cycles.
11
Flux application during the test run: (this function is only to be used by trained person-
nel) 11
Flux dots can be applied to a PCB but not component placed in order to check the dots, and
find the optimum setting.
Select the Processing off option from the Software options menu.
Check the Apply flux during test run check box [X].
Flux dots will now be applied, but no components will be placed.
The machine can also be run continuously without fluxing and without placing.
Select the Processing off option from the Software options menu.
Uncheck the Apply flux during test run check box [ ].
SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.9 Flux dispenser unit
519
11.9.7.4 Single functions
There are a number of Single Functions that allow you to operate the fluxing head independently
of the placement program. 11
Å Click on the Gantry functions icon from the main view.
11
Fig. 11.9 - 11 Single Functions - gantry
Å Click on the Gantry functions button from the Gantry functions view.
(See Fig. 11.9 - 12
).
11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.9 Flux dispenser unit Software version SR.407.xx 01/2001 US Edition
520
11
Fig. 11.9 - 12 Gantry functions
(1) Buttons for the fluxing single functions (flux)
Go to refill position: 11
To change the syringe, you must first move the syringe piston to its bottom position, and move the
machine into a suitable position (refill position). 11
Å Click on the Go to refill position button. The fluxer head will move to the refill position, and
the syringe piston will move down. The syringe can then be changed. See Section 11.9.5
Changing the syringe.
The fluxer head must be moved to the refill position before any work is carried out on it. The flux
must be refilled in this position. 11
Å Click on the Go to refill position button, and press the Start button. The fluxer head will move
to the refill position.