80S-20用户手册.pdf - 第303页
SIPLACE 80S -20/F4 User Manual 6 Vision functions Software version SR.407.xx 01/2001 US Edition 6.6 Test Component 303 Rectangle s: 6 dark blue :search window around th e entire leads group or arou nd ever y 6 light bl u…

6 Vision functions SIPLACE 80S-20/F4 User Manual
6.6 Test Component Software version SR.407.xx 01/2001 US Edition
302
Rectangles: 6
light blue:Search window for the position in the direction of the leads 6
dark blue:Search window for the position vertically to this 6
green:X and Y-tolerances 6
Star: 6
orange:Results: Location of the group in question 6
Comments: 6
Depending on which measurement algorithm was selected the middle or the end of the lead
group in the direction of the leads will be shown. 6
Cross: 6
white:Results of position recognition -> X and Y- angles 6
Overlays: 6
gray:Profile in the integration direction in question 6
blue:Gradients from the above profiles 6
yellow:Results from the geometric filter 6
red: Interpolation limits for position determination 6
light blue:Results of interpolation -> Position 6
Comments: 6
The overlay will be provided for both the light blue and the dark blue search window. 6
6
4. Lead mode 6
See Section 6.6.4.14
on page 323 for a definition of the measuring methods. 6
This measurement method can be recognized by 6
– either there being a window around a leads group (combined window, preset value)
– or there being a window around every single lead (separate window). You can modify the win-
dow types separate or combined window in the Measure mode Lead menu.
Procedure: 6
Each lead will be measured in a way similar to corner mode or the entire leads group will be mea-
sured. 6
6
6

SIPLACE 80S-20/F4 User Manual 6 Vision functions
Software version SR.407.xx 01/2001 US Edition 6.6 Test Component
303
Rectangles: 6
dark blue:search window around the entire leads group or around every 6
light blue:search window around the first lead in a group 6
green:X and Y-tolerances 6
Cross: 6
white:Results of position recognition X and Y-angles 6
Overlay:
gray:Profile in the integration direction in question 6
blue:Gradients from the above profiles 6
The gradients are only required and displayed for the profiles in the
direction of the leads. 6
yellow:Results from the geometric filter 6
red: Interpolation limits for position determination 6
light blue:Results of interpolation -> Position 6
Comments: 6
An overlay is available for both directions of interpolation. 6
Optical measurement of BGAs and flip-chips with the F placement machine 6
The crosshairs indicate the position of the component in the camera coordinates system. The
outline of the component will be emphasized by the use of color. 6
The measured values represent geometric component parameters such as 6
– position in the camera coordinates system
– rotation angle
– maximum offset of the balls in X and Y-directions
– factor for the quality of measurement
6
1. Grid mode 6
See Section 6.6.4.14
on page 323 for a definition of the measuring methods. 6
Grid mode works with preset pattern tolerances and is therefore to be regarded as the first mea-
surement step in the optical surveying of BGAs and flip-chips. To ascertain the approximate posi-
tion it will be adequate to measure just a few connections. 6
6 Vision functions SIPLACE 80S-20/F4 User Manual
6.6 Test Component Software version SR.407.xx 01/2001 US Edition
304
The number of balls to be measured and the pattern tolerances define the size of the search win-
dow. The rough position and the skew of the component are determined for each corner of the
component via a search window. This measurement method can be identified by 6
– the synthetic model being shown in pixel resolution at the lefthand edge of the video image,
and
– the 4 windows at the corners of the component.
Procedure: 6
– The algorithm defines 4 dark blue corner windows on the basis of the pattern tolerances and
the balls defined in the package form file. The default search value is 5 balls.
– A detection algorithm runs with the aim of detecting all balls corresponding to this type. Those
found will be marked with light blue crosses.
– The balls defined in the package form file are determined by the search algorithm. The balls
found are marked with a white outline. If defined balls are not found an error message will ap-
pear on the screen.
– From these data the rough position and the skew of the component are determined. The mea-
sured position of the component is marked with white crosshairs.
Rectangle: 6
dark blue:4 search windows, depending on the pattern tolerances and
the number of balls 6
Cross: 6
white:Ball model candidates found 6
Overlays: 6
white:Balls found which are defined in the package form file 6
Crosshairs: 6
white:Results of position recognition -> X and Y-angles 6
Star: 6
white:Center of the component -> Position 6
Synthetic model representation at the lefthand edge of the video image: 6
Image: Model in pixel resolution 6