80S-20用户手册.pdf - 第46页
1 Introduction SIPLACE 80S-20 /F4 User Manual 1.10 Setting up the placement machine Sof tware version SR.407.xx 01/2001 US Edition 46 1.10 Setting up the placeme nt machine 1.10.1 T ransport dimensions 1 Fig. 1.10 - 1 Di…

SIPLACE 80S-20/F4 User Manual 1 Introduction
Software version SR.407.xx 01/2001 US Edition 1.9 Dimensions and weight of the machine
45
1.9.3 Center of gravity of the machine
1
Fig. 1.9 - 2 Center of gravity of the machine
X coordinate - 80 mm
Y coordinate 0 mm
Z coordinate 350 mm high
T PCB transport direction 1
1
These center of gravity coordinates relate to machines with a PCB transport height of 830 mm.1

1 Introduction SIPLACE 80S-20/F4 User Manual
1.10 Setting up the placement machine Software version SR.407.xx 01/2001 US Edition
46
1.10 Setting up the placement machine
1.10.1 Transport dimensions
1
Fig. 1.10 - 1 Dimensions of the placement machine during transportation and setting up
A Points for attaching the pallet jack (fork length 1600 mm) 1
(1) Length 1587 mm
(2) Width 1921 mm
(3) Height 1836 mm
(4) Input conveyor
(5) Output conveyor
1
The PCB transport height is 830 mm ± 15 mm. 1
SIPLACE 80S-20/F4 User Manual 1 Introduction
Software version SR.407.xx 01/2001 US Edition 1.10 Setting up the placement machine
47
1.10.2 Transport configuration and transportation
The following components are not installed when the placement machine is delivered from the fac-
tory: 1
– Keyboards
– Monitors
– Fault indicator lamps and
– Changeover tables
Å Install the dismantled components for commissioning.
Å Use a pallet jack with a minimum fork length of 1600 mm to transport the machine.
Å Attach the pallet jack only at the indicated points.
1.10.3 Quality of the foundation
Å Ensure that
– you set up the machine on a firm and non-vibrating foundation.
– the load bearing capacity per unit area of the foundation is greater than 1000 kg/m².
1.10.4 Compressed air supply
– The pressure of the compressed air supply must be at least 5.5 bar (max. permissible value
8bar).
– The compressed air must conform to the above specification.
This can be achieved with 1
– Oil-free compressors, e.g. Atlas, Copco type ZR4
– Compressed air washer/dryers
– Micro-filters, series X, e.g. from Zander
1.10.5 Power supply
– The power socket must be fused with the following fuse ratings:
3 x 16 A for 3 x 400 VAC / 3 x 208 VAC 1