80S-20用户手册.pdf - 第527页

SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware Software version SR.407.xx 01/2001 US Edition 11.12 Fine calibration 527 The foll owing parts may be ordere d if requir ed: 11 – Magazin e with gla ss compone…

100%1 / 570
11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.12 Fine calibration Software version SR.407.xx 01/2001 US Edition
526
11.12 Fine calibration
11.12.1 Overview
Fine calibration involves measuring the machines placement offset and determining the required
correction from this value. The Fine calibration measuring program is integrated into the SITEST
program, and a detailed description of the measuring procedure is given in the Fine calibration
instructions (article no. 00191655-01). 11
CAUTION
The SITEST program is password-protected. It must only be called up and used by Siemens en-
gineers or appropriately trained personnel. 11
11.12.2 System requirements
The following system requirements must be fulfilled in order to use the fine calibration program:11
Machine type S-20/F
4
Station computer software version 406.xx or later
SITEST version 406.xx or later
11.12.3 Measuring equipment and tools
The following are supplied as standard: 11
Mapping plate (glass plate in a metal frame)
Double-sided transparent adhesive film
Lighting unit
Magazine with glass components for the collect&place head and pick&place head with fine-
pitch vision module.
11
The following items must be ordered: 11
Manual tray (waffle tray holder) to hold the magazine for the glass components
(article number 00116430-xx)
11
11
SIPLACE 80S-20/F4 User Manual 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.12 Fine calibration
527
The following parts may be ordered if required: 11
Magazine with glass components for the collect&place head and pick&place head with flip-chip
vision module (article number 00343704-xx)
11.12.4 Functional description
First select the placement program for fine calibration by selecting the Cluster for fine calibration
option from the Options pull-down menu. Then process the mapping plate with the glass compo-
nents from a magazine on the manual tray. 11
After placement, start the SITEST program and start the Fine calibration measuring program.
The placement head (collect&place head or pick&place head) will measure the current placement
positions of the glass components and compare these positions with the circular fiducials on the
mapping plate. The results are used to calculate the offset values. 11
The offset values are used to determine corrected values, which are then entered in the machines
machine data. 11
11
11
11 Station extensions /Hardware SIPLACE 80S-20/F4 User Manual
11.13 Vacuum tooling Software version SR.407.xx 01/2001 US Edition
528
11.13 Vacuum tooling
Vacuum tooling is another module that is used to increase the placement accuracy for concave
PCBs. The vacuum surface of this device picks up concave PCBs during processing and aligns
them so they are flat. 11
The vacuum tooling module can be used on both single and dual conveyors, and is fitted to the
lifting tables. 11
11.13.1 Description of the functions
The PCB is fed to the processing belt, where it is stopped. The lifting table moves up and the vac-
uum circuit for the vacuum tooling device is opened. The PCB is then held in place by the vacuum
tooling device, which is pressed with a spring action against the PCB by the lifting table. This
causes the suction cups of the tooling device to press against the PCB and hold it firmly in position.11
The vacuum channels are vented after placement. The lifting table is lowered, the PCB is re-
leased, and can then be moved on. 11
11
11