YG300_Ope_E.pdf - 第29页
1-1 1 Part names and functions 1 . M a c h i n e m a i n u n i t A s t a n d a r d m a c h i n e h a s t h e f o l l o w i n g c o n f i g u r a t i o n s a f t e r i n s t a l l a t i o n i s c o m p l e t e . N a m e s…

Chapter 1 Part names and functions
Contents
1. Machine main unit 1-1
2. Operation panel and data input unit 1-
4
2.1 Keyboard and mouse 1-4
2.2 Operation panel buttons 1-
5
3. Head assembly 1-6
3.1 Component pick-and-place head 1-6
3.1.1 Eight-in-line multi-head (FNC) assembly 1-6
3.2 Nozzle types 1-7
3.2.1 Nozzles for the eight-in-line head assemblies 1-7
3.3 Nozzle station (option) 1-8
4. Component supply section 1-9
4.1 Supplying components from feeder plates 1-9
4.1.1 Fixed feeder plates 1-9
4.1.2 Feeder exchange carriage 1-11
5.
Conveyor unit and component recognition system
1-13
6. Machine layout 1-1
4
7. Axis configuration 1-1
7
8. Side-view camera 1-1
8
9. Blow station 1-1
9
9.1 Performing a nozzle shaft blow 1-20

1-1
1
Part names and functions
1. Machine main unit
A standard machine has the following configurations after installation is complete. Names and functions of
major parts of the main unit are illustrated below.
Signal light
Operation panel and
data input unit
Power switch
[RECOVER] button
I/O signal
connectors
Alarm buzzer
Safety cover
Feeder setup section
Pressure
gauge
Front panel
Head
assembly
Air pressure supply/shutoff switch
Power connection terminals
USB drive
CD-ROM drive
FDD drive (option)
Machine main Unit
23100-M3-00

1-2
1
Part names and functions
n
Signal light
Indicates current operating conditions of the mounter with a green, yellow and red light explained below.
Machine status Example Green Red Yellow
Warm-up or automatic operation ON ----- -----
Emergency stop ----- ON -----
System error
(with buzzer ON)
• Excessive current
• Secondary limit over
----- ON -----
Particular part placement table
stopped due to error
(with buzzer ON)
• Pickup error, recognition error, etc. ON ----- Flashing
Entire machine stopped due to error
Board data check error, etc
(with buzzer ON)
• Board transfer error, data check
error, etc.
----- ----- ON
Components cannot be used.
• Components run out.
Tray changer door is opened.
• Non-stop exchange carriage is off.
----- ----- Flashing
Dump station is full. (When the option is installed) ----- ----- Flashing
n
Alarm buzzer
This buzzer sounds if an error or abnormal operation occurs. (Volume can be adjusted by turning the buzzer ring right or
left.)
n
Safety cover
This cover must be closed during operation. If opened, emergency stop is triggered.
n
Pressure gauge
Shows the supply air pressure (upper display) and pressure-drop detection level (lower display).
A normal pressure value is shown in green, and an abnormal pressure value in red.
Use the pressure regulator knob and the arrow buttons on the pressure gauge to set each pressure value as follows:
• Supply air pressure (upper display) : 0.55 MPa
• Pressure-drop detection level (lower display) : 0.45 MPa
n
Head assembly
Picks up and mounts components with the nozzles at the tip. Also has a camera for recognizing marks on board. (See "3.
Head assembly" in this chapter.)
n
Front panel
Installed behind this panel are the system mother board, power supply board, servo control board, vision board and
CD-ROM drive.Keep this panel closed during operation.
n
Power switch
Turns on or off the power to the machine. The power is on when turned to the right.
c
CAUTION
Wait about 2 seconds before turning the power switch back on after turning it off.