YG300_Ope_E.pdf - 第68页

2-15 2 Basic operation 4 . [L e f t ] b u t t o n , [ R i g h t ] b u t t o n M o v e s t h e c o n v e y o r m o t o r i n t h e l e f t o r r i g h t d i r e c t i o n a t h i g h s p e e d s . 5 . [L o w L e f t ] b u…

100%1 / 117
2-14
2
Basic operation
3. [Axis] button
Pressing this button opens the "Move Axis" window as shown below. You can manually move each axis at a specified
step stroke with the arrow buttons or to a specified position with the [PTP] button.
"Move Axis" screen
1
2
3
4
5
6
24207-M3-00
Button name Function
1 Zoom in/out (+, -) Zooms in or out the image. (16 times to 1/16 times)
2 Mark Light Allows changing mark lighting manually. Using this button does not affect data.
3 PTP
Displays the "PTP" dialog box that allows directly specifying the position where
you want to move the selected axis.
4 Step Mode
When this button is pushed in, the selected axis can be moved in "step mode
(inching mode)" with the arrow buttons at a specified step stroke (inching
stroke).
5 Arrow Use these buttons to move the selected axis in the desired direction.
6 Brake
Use this button when you want to release the brake during emergency stop.
(W-axis and PU axis only)
The brake is automatically released when the servo is turned on.
2-15
2
Basic operation
4. [Left] button, [Right] button
Moves the conveyor motor in the left or right direction at high speeds.
5. [Low Left] button, [Low Right] button
Moves the conveyor motor in the left or right direction at low speeds.
6. [Push Up] buttons (A to D)
Raises or lowers each push-up plate. The board edge clamp also moves up or down simultaneously.
7. [Exit Stopper] button, [Entrance Stopper] button
Raises or lowers the exit stopper or entrance stopper.
8. [Transfer 1 Claws 1 to 3], [Transfer 2 Claws 1 to 3] buttons
Use these buttons to lower or raise the T-axis transfer claws.
[Transfer 1 Claw 1], [Transfer 2 Claw 1]
Lowers and raises the transfer claws closest to the board exit side.
[Transfer 1 Claw 2], [Transfer 2 Claw 2]
Lowers and raises the transfer claws in the second to fourth positions from the board entrance side.
[Transfer 1 Claw 3], [Transfer 2 Claw 3]
Lowers and raises the transfer claws closest to the board entrance side.
[Transfer 1 Claws 1 to 3], [Transfer 2 Claws 1 to 3] buttons
T2
T1
T2
T1
N Right-to-left board flow
N Left-to-right board flow
Board
Board
23201-M3-00
2-16
2
Basic operation
n
Manual head operation
[Unit] – [Head] screen
1
2
3
4
5
24208-M3-00
Button name Function
1 Vacuum Turns the vacuum of each head on or off.
2 Blow Turns the air blow in each head on or off.
3 Nozzle Change
Opens the "Nozzle Change" dialog box.
Specify the head and nozzle type to
perform nozzle change.
4 Current Nozzles
Shows a list of nozzle types currently
attached to each head.
5 Axis
Opens the "Move Axis" screen. This is the same as the [Axis] button on the [Unit]-
[Conveyor] screen.