YG300_Ope_E.pdf - 第54页
2-1 2 Basic operation 1 . B e f o r e o p e r a t i o n T h e f o l l o w i n g e x p l a i n s h o w t o c a n c e l e m e r g e n c y s t o p a n d c l e a r e r r o r s . R e a d b e f o r e o p e r a t i n g t h e m …

Chapter 2 Basic operation
Contents
1. Before operation 2-1
1.1 Canceling emergency stop 2-1
1.2 Clearing an error 2-
2
1.3 Typical errors and troubleshooting 2-
3
2. Operation screen and buttons 2-8
2.1 Basic configuration of operation screen 2-8
2.2 Setup screen 2-1
1
2.3 Unit screen 2-1
2
3. Starting and stopping the machine 2-19
3.1 Pre-operation check 2-20
3.2 Starting the machine 2-2
1
3.3 Warming up the machine 2-2
3
3.4 Adjusting the conveyor unit setup 2-2
5
3.4.1 Conveyor unit setup flow 2-26
3.5 Preparing the component supply unit 2-28
3.5.1 Tape feeder 2-28

2-1
2
Basic operation
1. Before operation
The following explains how to cancel emergency stop and clear errors. Read before operating the machine.
n
Cautions during machine operation
• Do not turn off the compressed air during operation. The machine may malfunction, as pneumatic devices are not
correctly controlled.
• Before beginning maintenance work, always make sure that no air pressure remains in air cylinders.
n
Cautions during power outages
If a power outage (blackout) occurs during automatic machine operation, always turn the main power switch off to
prevent faulty operation after power has been restored. If any boards are left in the machine, remove them.
1.1 Canceling emergency stop
Follow these steps to cancel emergency stop.
1
Release the emergency stop button.
When the emergency stop button is pressed, turn it clockwise to release it.
2
Check safety.
Before continuing the procedure, check the surrounding area for safety.
3
Press the [READY] button.
Pressing the [READY] button on the operation panel turns on the servomotors.
c
CAUTION
The [READY] button is enabled only when the [ACTIVE] button next to it is turned on.
[READY] button
Press the [READY] button to turn on the servo.
24200-M3-00
4
Check the signal light and screen display.
Check that the red lamp of the signal light is off and the emergency stop sign on the top left (status
area) of the operation screen is now off.

2-2
2
Basic operation
1.2 Clearing an error
If an error occurs a buzzer sounds and a warning screen appears. To clear the error, use the following steps.
1
Turn off the buzzer.
Press the [ERROR CLEAR] button on the operation panel or the [BUZZER OFF] button on the error screen
to turn off the buzzer.
2
Check the cause of the error.
Possible causes are displayed on the lower part in the error screen, so check or make a note of the
description.
3
Clear the error screen.
Press the [ERROR CLEAR] button again or the [ERROR CLEAR] button on the error screen to clear the
error screen.
4
Check the signal light and screen display.
Check that the yellow lamp of the signal light is off and the error message on the left of the status area
on the operation screen is now off.