YG300_Ope_E.pdf - 第59页
2-6 2 Basic operation n D a t a - r e l a t e d e r r o r s C o d e E r ro r n a m e a n d d e s c r i p t i o n E a 0 0 0 3 6 V AC U U M L E V E L E R RO R S t a t e V a c u u m l e v e l h a s n o t r e a c h e d t h e…

2-5
2
Basic operation
n
Conveyor-related errors
Code Error name and description
Ea00070
BOARD TRANSFER ERROR
State Unexpected board is on the conveyor.
Cause
Board was carried in from upstream side even though no board request signal was output, or an abnormal
board was detected.
Action
Readjust the position of conveyor exit sensor on upstream side, or the position of conveyor carry-in sensor or
board detection sensor at the entrance stopper of this machine.
Ea00074
BOARD FIXING ERROR
State Board trans-unit, locate pin or push-up unit does not respond to command.
Cause Senor position adjustment is inappropriate, or speed control is set too low to maintain stable movement.
Action Check the sensors for conveyor unit height to see if they are operating properly.
Ea00831
MAIN STOPPER INTERLOCK
State
Operation of the main stopper in this table height cannot be performed.
-Please lower the Board table.
Or You can't move table on dangerous position, because the main stopper is upper.
-Please move main stopper down.
Cause Main stopper is raised, creating a dangerous situation.
Action Lower the main stopper.
Ea00851
INTERLOCK ERROR
State Transfer axis up/down sensor is OFF. Remove the cause of this sensor being OFF.
Cause Board conveyor unit is left lowered, or sensor error occurred.
Action Check the conveyor unit for up/down movement.
Ea00852
INTERLOCK ERROR
State The sensor for main stopper, push-up or entrance stopper is ON. Remove the cause of this sensor being ON.
Cause Sensor is defective or actuator operation is poor.
Action Check the conveyor unit for up/down movement.
Ea07876
CAN NOT EXECUTE COMMAND
State
Failed to execute this command, because the push-up unit's position is not enough low. Please execute this
command after moving it down again,
Cause Unable to run this command since servo push-up is not sufficiently lowered.
Action Lower the servo push-up by conveyor unit operation or reset, then re-run this command.

2-6
2
Basic operation
n
Data-related errors
Code Error name and description
Ea00036
VACUUM LEVEL ERROR
State Vacuum level has not reached the specified level. The component might have dropped after recognition.
Cause
Pickup vacuum pressure is not appropriate, or component is not correctly picked up. Component pickup
position coordinate is inaccurate or pickup accuracy is poor.
Action
Make adjustment so that the component is picked up properly, then readjust the pickup vacuum pressure in
Adjust mode.
Ea00267
FIDUCIAL FINE CORRECTION ERROR
State
Failed to adjust the XY position for FINE mode within limit. The limit is specified as FINE mode in machine
data.
Cause Correction range is too narrow.
Action Widen the correction range.
Ea00502
DATA READING ERROR
State Failed to read data.
Cause File may be destroyed.
Action Relevant data cannot be loaded. If backup data is available, copy and load it.
Ea00503
BOARD DATA ERROR
State Failed to write data.
Cause Hard disk is full or disk has errors.
Action First check the disk condition. If the number of files is too high, reduce the number of files, then retry.
Ea02702
NOZZLE STATION MACS ERROR
State Failed to execute Nozzle Station MACS. Please check the machine data, and mark data in mark database.
Cause Failed to recognize marks while recognizing nozzle station MACS to perform a nozzle change.
Action Correct the positions of nozzle station MACS, or set the correct mark database No.

2-7
2
Basic operation
n
Others
Code Error name and description
Ea00109
EMERGENCY STOP FUNCTION DURING MOUNT
State
EMERGENCY STOP FUNCTION is executed duringmounting sequense. So, there is danger that
mountsequense finished under the unusual condition. Can it stop automatically after it installs it when an
automatic driving is restarted, and the image at the installation position be confirmed.
Cause Emergency stop was triggered during component placement.
Action Use "trace" to check whether the component is placed at the specified point.
Ea00818
QUICK STOP ACTIVE
State QUICK STOP FUNCTION is now active.
Cause Emergency stop was triggered by the "conveyor width safety check sensor".
Action Check the status of the conveyor width safety check sensor.
Ea01023
WARNING: NOT ENOUGH HDD SPACE
State
Free space on Hard Disk is less than 10MB. To avoid the possibility that you cannot save new data anymore
and that data might be lost, it is best to create new space on the hard disk now. Copy unused Board data to
floppy disks and delete it from the hard disk.
Cause Board data are too many.
Action Make a backup of unnecessary board data and delete those data from the hard disk.
Ea02722
DON'T YOU NEED HALFWAY CONTINUE?
State
A board that is not finished to mount exist on the mounting position. If you continue auto running, a halfway
board may be transferred. Please confirm the board condition and execute halfway continue command if
necessary.
Cause
A board for which component mounting is not completed is left in the component placement position. If
automatic operation continues as is, then the unfinished board may be transferred downstream.
Action
Check the board in the component placement position. When it is not finished, run "Halfway Continue"
command to resume component mounting on that board.
Ea02889
EMERGENCY STOP FUNCTION DURING PICK
State
EMERGENCY STOP FUNCTION is executed during picking sequence. There is a chance that the picking
sequence finished under suspicious conditions. Please check condition of the component.
Cause
Emergency stop was triggered during component pickup. Component pickup operation might have been
unstable.
Action Check how the component is being picked up.
Ea07871
CAN NOT EXECUTE COMMAND
State
Can not execute this command , because RESET is not finished completely. Please try the RESET command
again, and finish it.
Cause Unable to run commands since reset is not complete.
Action Perform a reset again.
Ea01277
X1 Axis 2nd LIMIT OVER
State Move the axis until error message disappears. The "EMERGENCY STOP" light will go off.
Cause X1-axis secondary limit was exceeded.
Action Move the X1 axis by hand to a safe position.
Ea01278
Y1 Axis 2nd LIMIT OVER
State Move the axis until error message disappears. The "EMERGENCY STOP" light will go off.
Cause Y1-axis secondary limit was exceeded.
Action Move the Y1 axis by hand to a safe position.