3 Replacing spare parts Se rv ic e Ma nu al P ro ce ss L en s PL - 0 3/ 20 25 11 9 3.5.2.2 Changing the conveyor motor Parts 03110463-xx BLM-6080-24 motor Equipment and tools ● Allen key size 4.0 Requirements ● Machine i…

100%1 / 168
3 Replacing spare parts
118 Service Manual Process Lens PL - 03/2025
Fig.162: Conveyor belt
Check the tension of the belt at the meas-
urement point (1) using a tension meter.
The tension should be 250 +/- 10 Hz.
The steps for the other conveyor system
are the same.
Installation
Follow the removal instructions in reverse order for installation.
Check the function of the conveyor belt
Requirements
Machine is switched on.
Inspection circuit board is placed at the beginning of the machine.
Fig.163: “Unit Function” tab
Go to the diagnostic page.
Click on the tab Unit function(1).
Go to the section Conveyor(2).
Click the button PCB In(3) and the button
PCB Out(4).
3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 119
3.5.2.2 Changing the conveyor motor
Parts
03110463-xx BLM-6080-24 motor
Equipment and tools
Allen key size 4.0
Requirements
Machine is switched off.
Fig.164: Overview of the conveyor motor
1. Conveyor motor belt
2. Conveyor motor
3. Width adjustment belt
4. Width adjustment motor
Fig.165: TSP400
Disconnect the connectors(1) for the con-
veyor motor from the TSP400(2).
3 Replacing spare parts
120 Service Manual Process Lens PL - 03/2025
Fig.166: Conveyor motor (from back)
Unscrew the 4 screws(1) using an Allen
Key size 4.0.
Take off the conveyor motor belt(3).
Take out the motor of the machine.
Fig.167: Conveyor motor
Unscrew the screw(3) off the gear(2) of
the old motor(1) and replace it onto the
new motor using an Allen Key size 4.0.
Put the motor back in place.
Put the belt on and tighten the screws.
Connect the connectors to the TSP400.
Installation
Follow the removal instructions in reverse order for installation.
Check the function of the conveyor motor
Requirements
Machine is switched on.
Circuit board is placed at the beginning of the machine.