3 Replacing spare parts 64 Se rv ic e Ma nu al P ro ce ss L en s PL - 0 3/ 20 25 Checking free movement of lifting table After all work on the lifting table mechanics check the free movement of the lifting table. Fig.83…

100%1 / 168
3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 63
Fig.81: Fastening screws
Remove the three screws(1) fastening the
retaining bracket.
Dismantle the cover over the conveyor control board.
Unthread the cable up to the conveyor control and then unplug it at connection X10. You may
want to mark the position to make clear assignment easier later on.
See also: 3.5.1.7.1.1 "Conveyor control TSP420 [03087642-xx]" [}110]
Remove the lifting table motor from the machine.
Fig.82: Motor crank and brackets
The motor crank(4) and the brackets(2) need
to be removed and refitted on the new lifting
table motor.
Remove the two screws(1) fastening the
brackets(2).
Remove the screw(3) fastening the motor
crank(4).
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instructions:
CAUTION
Installation instructions
The motor crank and the brackets need to be removed and refitted on the new lifting table motor.
Use the old lifting table motor as a reference.
Observe the position and number of washers used.
Tighten the clamping screw on the motor crank.
Make sure that the motor connection cables do not rub against any parts.
Place the lifting table plate onto the guidance pins. Make sure that the fastening screws slide
properly into the precut thread.
Check the free movement of the lifting table (see Checking free movement of lifting table).
Calibrate the lifting table motor and then perform a reference run (see Calibrating the Conveyor
Functions).
For more information about the conveyor control refer to section 3.5.1.7.1.1 "Conveyor control
TSP420 [03087642-xx]" [}110].
3 Replacing spare parts
64 Service Manual Process Lens PL - 03/2025
Checking free movement of lifting table
After all work on the lifting table mechanics check the free movement of the lifting table.
Fig.83: Lifting the table
Click on this icon(1) to enter the settings menu.
Click on Unit Function(2) to enter the settings user menu.
Switch to the operator level Machine service or better.
In the Conveyor aera click on Lift Home(3) to move the lifting table to the home position.
Click on Lift up(4) and Lift Down(5) to ensure all lifting mechanical parts are not obstructed or
there are any assembly issues.
3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 65
Calibrating the lifting table motor
After completing the work on the lifting table, this will need to be calibrated.
Procedure
Fig.84: Enterring the calibration menu
Click on this icon(1) to enter the settings menu.
Click on Unit Function(2) to enter the settings user menu.
Switch to operator level Machine service.
Click on System Test(3) to enter the calibration menu.
Fig.85: Calibration