3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 31
Installation
Follow the removal instructions in reverse order for installation. Also observe the following
instruction:
Fig.23: Aligning the module
Align the module with the help of the two guide pins.
Checking for connectivity
NOTICE
Make sure the machine is installed with the latest software version. Otherwise, the DLP Test software
will return an error message.
Fig.24: Checking connectivity
3 Replacing spare parts
32 Service Manual Process Lens PL - 03/2025
Open the file c:\wineagle\utilities\tools\DLP\DLP_G2\DLPG2Library_Tester(1) on the station
computer.
Select Left DLP ModuleID:0(2) and right DLP ModuleID:1(2) one at a time.
Click on Get Version (3).
ð The data shown mean that DLP is connected to DMD(4).
Start the Process Lens station software from your Windows Desktop.
Checking B/A Value
Click on the
button at the bottom of menu on the GUI.
Fig.25: 2D/3D Calibration
Select the Calibration tab(1).
Under 2D/3D Calibration(2) click on
Start(3).
ð The jig is transported from the input
section of the conveyor to the inspec-
tion area.
Follow the GUI instructions.
Fig.26: Connecting the backlight cable
Connect the backlight cable.
At the end of the GUI instructions click OK to proceed.
3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 33
Fig.27: Stop button
Click Stop when the vision reaches the jig
position.
Fig.28: Adjusting focus
Click on the LIVE image(1) to move the
vision to the 3D jig until the 3D image
appears.
Adjust the focus(2) to 60 till 70.