Process Lens PL Service Manual_EN.pdf - 第66页
3 Replacing spare parts 66 Se rv ic e Ma nu al P ro ce ss L en s PL - 0 3/ 20 25 ► In the Track Width Calibration area(4) select the right track. ► Click on the Lift Table Calibration button (5) to calibrate right trac…

3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 65
Calibrating the lifting table motor
After completing the work on the lifting table, this will need to be calibrated.
Procedure
Fig.84: Enterring the calibration menu
► Click on this icon(1) to enter the settings menu.
► Click on Unit Function(2) to enter the settings user menu.
► Switch to operator level Machine service.
► Click on System Test(3) to enter the calibration menu.
Fig.85: Calibration

3 Replacing spare parts
66 Service Manual Process Lens PL - 03/2025
► In the Track Width Calibration area(4) select the right track.
► Click on the Lift Table Calibration button(5) to calibrate right track of the lifting table.
► Repeat the calibration the same way for the left track.
3.5.1.3 Conveyor drive
Replacing the conveyor drive
Parts
Fig.86: Conveyor drive
03093387‑xx DC drive motor with synchronizing disk SXa
Equipment and tools
00326015‑xx Belt tension measuring device
00353832-xx Allen key set
00096290-xx Fork wrench set
Side cutter
Cable tie

3 Replacing spare parts
Service Manual Process Lens PL - 03/2025 67
Overview
Fig.87: Overview of the conveyor drives
1 Conveyer Track 1 2 Conveyer Track 2
3 Conveyor drive input conveyor track 2 4 Conveyor drive placement area track 2
5 Conveyor drive output conveyor track 1 6 Conveyor drive output conveyor track 2
7 Width adjustment motor track 1 8 Width adjustment motor track 2
9 Conveyor drive input track 1 10 Conveyor drive placement area track 1
Removal
► Use the software or manually move the conveyor rail into a position which allows you best
access.
To move the conveyor side wall manually, pull the toothed belt of the width adjustment unit.
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation.
► The fastening screws of the conveyor drives are on the outer side of the conveyor.