DECAN_S2_Admin(Eng_Ver4.5).pdf - 第104页

4-23 Tools Shortcut M enu  <Position> group  <Light> button  Outer Adjusts the outer lighting for the Down Camera of the selected Gantry .  Inner Adjusts the inner lighting for the Down Camera of the sele…

100%1 / 609
4-22
Advanced Chip Shooter DECAN S2 Administrator’s Guide
Clicking the <Advanced Surface Measure> button will display the following dialog
box.
<Spread> group
The X and Y values are registered automatically by calculating the margin
inputted in the <InitialXY> group.
<Point> column
Refers to the position at which the board flatness is to be measured.
<X> column
Refers to the X position value of the flatness measuring position.
<Y> column
Refers to the Y position value of the flatness measuring position.
<Z1~4> column
Refers to the Z height value measured at the X and Y positions.
<MAX> row
Shows the maximum value among the Z values obtained by measuring them
at the nine points on the board.
<MAX> row
Shows the average Z value obtained by measuring the values at nine points on
the board.
<MIN> row
Shows the minimum value among the Z values obtained by measuring them at
the nine points on the board.
4-23
Tools Shortcut Menu
<Position> group
<Light> button
Outer
Adjusts the outer lighting for the Down Camera of the selected Gantry.
Inner
Adjusts the inner lighting for the Down Camera of the selected Gantry.
<Move> button
Move the fiducial camera of the selected gantry.
<Get> button
Applys the coordinate value of the current position as the selected fiducial
mark position.
<PrevMove> button
The fiducial camera moves from the current position to the previous position.
<NextMove> button
The fiducial camera moves from the current position to the next position.
<InitialXY> group
<MarginX> editbox
Refers to the margin in the X direction of the board.
<MarginY> editbox
Refers to the margin in the Y direction of the board.
1: MatginY
2: MarginX
<Clear> button
Deletes the teaching values of the Z-column in the <Spread> group.
4-24
Advanced Chip Shooter DECAN S2 Administrator’s Guide
Ref. Once the value of the teaching of the deleted Z column can not be
undone.
<Offset Check> group
<Head> combo box
Selects the head to measure the board flatness.
<PrevDetect / NextDetect> button
<PrevDetect> button: Measures the previous coordinate value of the
coordinate currently selected in the <Spread> group.
<NextDetect> button: Measures the next coordinate value of the coordinate
currently selected in the <Spread> group.
Ref. The <PrevDetect / NextDetect> button is enabled when the
<Manual> check box is selected.
<Manual> check box
Teach the Z values at the X and Y coordinates manually using the
<PrevDetect / NextDetect> button.
<Detect Z> button
Teach the Z value for the X and Y coordinates of the cell currently selected in
the <Spread> area.
<Automatic> check box
After selecting the Z column to be measured in the <Z> combo box, pressing
the <Detect Z> button will measure the Z column automatically.