DECAN_S2_Admin(Eng_Ver4.5).pdf - 第481页

15-30 Advanced Chip Shooter DECAN S2 Admi nistra t or’s Guide 12. Select the LM_MAP_FL Y in the <Open> dialog box and click the <Open> button. 13. Once the file import is completed, check whether light mappin…

100%1 / 609
15-29
System Setup
11. Check the <Import All> check box in the <Select Camera> group and click the
<Import> button.
15-30
Advanced Chip Shooter DECAN S2 Administrator’s Guide
12. Select the LM_MAP_FLY in the <Open> dialog box and click the <Open> button.
13. Once the file import is completed, check whether light mapping data values increase
gradually from Level 0 to Level 15. Then click the <Update> button.
15-31
System Setup
Ref. The test result value must be within ±10 from the following reference
value.
14. Select Gantry 2 in the <Gantry> combo box and perform calibration in the same
manner as has been done for Gantry 1.
Side Outer Coaxial
0 0 0 0
1 0 0 0
2 0 0 0
3 0 35 8
4 35 59 12
5 45 113 16
6 56 155 20
7 66 203 25
8 77 136 30
9 87 159 35
10 98 167 40
11 108 174 45
12 119 180 50
13 130 185 55
14 140 190 60
15 151 191 65