DECAN_S2_Admin(Eng_Ver4.5).pdf - 第106页
4-25 Tools Shortcut M enu 4.7.2. Head Tab dialog box Performs setup of camera lighting or check o f head operation by manually recognizing parts with vision system. Figure4.8 “Manual Control – Head” dialog box <Gant…

4-24
Advanced Chip Shooter DECAN S2 Administrator’s Guide
Ref. Once the value of the teaching of the deleted Z column can not be
undone.
<Offset Check> group
<Head> combo box
Selects the head to measure the board flatness.
<PrevDetect / NextDetect> button
<PrevDetect> button: Measures the previous coordinate value of the
coordinate currently selected in the <Spread> group.
<NextDetect> button: Measures the next coordinate value of the coordinate
currently selected in the <Spread> group.
Ref. The <PrevDetect / NextDetect> button is enabled when the
<Manual> check box is selected.
<Manual> check box
Teach the Z values at the X and Y coordinates manually using the
<PrevDetect / NextDetect> button.
<Detect Z> button
Teach the Z value for the X and Y coordinates of the cell currently selected in
the <Spread> area.
<Automatic> check box
After selecting the Z column to be measured in the <Z> combo box, pressing
the <Detect Z> button will measure the Z column automatically.

4-25
Tools Shortcut Menu
4.7.2. Head Tab dialog box
Performs setup of camera lighting or check of head operation by manually recognizing
parts with vision system.
Figure4.8 “Manual Control – Head” dialog box
<Gantry> combo box
Select the gantry to which the head to be tested belongs.
<Head Inspection> group
<Move all head to align height> button
Put the nozzle tip of the head at the align height for parts recognition.
<Mirror Open/Close> button
Open or close the mirror for parts recognition.
<Nozzle Put All> button
Return all nozzles placed at the head to the ANC.
<Part Dump All> button
Dump all the picked up parts at the dump box.
<Camera Select & Light Change> group
Set the illumination value of the fly camera. Select the fly camera whose illumination
is to be adjusted and adjust the slide bar in the <Light Value> group to adjust the
brightness.

4-26
Advanced Chip Shooter DECAN S2 Administrator’s Guide
<Threshold Value[0-255]> group
Images seen through SMVision consist of each pixel. In accordance with the
brightness, each pixel has a unique value ranging between 0 and 255. Here, ‘Threshold
Value’ signifies the border value determining whether each pixel should be recognized
in white or black. In the above figure, MMI is setup to be recognized as white when
the value is 100 or higher, and black when the value is less than 100.
<Real Display/Binary> button
Shows the image seen through SMVision in real display as seen by the naked eye
or binary image recognized by MMI.
4.8. Dump Information (Place Error Information)
Used for confirming the message window indicating the contents on the abandoned parts
by placement error and feeder.
Figure4.9 “Dump Information (Place Error Information)” dialog box
<Move> button
Moves the fiducial camera to the position at where an error has occurred.
<Move Next> button
Moves the fiducial camera to the position at where an error has occurred.
<Edit> button
Used to open the “Feeders” dialog box and edit the data related to the tape feeder, stick
feeder and tray feeder. For further details, refer to “8.1 Feeder [F4]”.
<Pusher U/D> button
Selects the feeder to which an error occurred in the list box for feeding.
button
Stops the sound of the buzzer.
<Close> button
Close the corresponding dialog box.