DECAN_S2_Admin(Eng_Ver4.5).pdf - 第139页
6-26 Advanced Chip Shooter DECAN S2 Admi nistra t or’s Guide Closes the <Fid u cial Position & Mark> dialo g box without saving the fiducial mark data. 6.3.1. Fiducial Mark Setup Order 1) Block Setup Omitted fo…

6-25
Board Definition
<Outline/Real> button
Shows the image seen through the Vision in real display to which threshold is not
applied, or in the image (Binary) to which threshold is applied as recognized by MMI.
<Test> button
By using the registered mark information, tests the fiducial mark.. The accuracy of the
registered mark data can be verified. When the test is successful, the following
message box is displayed.
<Scan> button
Executes a scan test on the set fiducial mark. Mark recognition is performed to
minimize the teaching offset for the center points (2 points) of the fiducial mark.
Move the fiducial camera to the position of the set coordinate and recognize the mark.
After recognition of the mark, the offset is indicated as shown in the following figure.
When it is desired to compensate the offset, select “Yes”.
When placing the IC part whose lead pitch is 0.5, use this function to perform
compensation for the fiducial mark.
<OK> button
Saves the fiducial mark data and closes the <Fiducial Position & Mark> dialog box.
<Cancel> button

6-26
Advanced Chip Shooter DECAN S2 Administrator’s Guide
Closes the <Fiducial Position & Mark> dialog box without saving the fiducial mark
data.
6.3.1. Fiducial Mark Setup Order
1) Block Setup
Omitted for non-block PC
2) Position Type’ setup
3) Mark Position’ setup
Select a fiducial mark in the <Mark Position> group.
Click the <Move> button to move the fiducial camera to the selected fiducial mark.
Perform adjustments so that the center of the fiducial mark falls on the crosshair center
of the SMVision window.
Click the <Get> button to input the coordinate of the fiducial mark.
4) ‘Mark List’ setup
5) ‘Form Data’ setup
6) Outline check
Click the <Outline> button to check if the outline seen in the SMVision window falls
on the fiducial mark outline.
If not, revise the “Shape Information’.
7) Fiducial mark recognition test
8) Tuning

6-27
Board Definition
Perform tuning at least more than twice.
9) Reflect set value: Click the <Update> button
6.3.2. Definition of fiducial mark
The method to define the fiducial mark size for a PCB length is as follows:
Length less than 800 mm: Same as the method to set general boards.
Length is 800 mm ~ 1,500 mm: Set multi work area.
6.3.2.1. Fiducial mark setup
When placing parts on a 0.8~1.2 m long PCB, set 3~4 fiducial marks on it, one of which
must be at the position to which the fiducial camera of the gantry can move.
When setting 3 fiducial marks, they can be set as shown in the following figure.
1) Transfer the PCB to the first workstation.
2) Teach the fiducial mark at center and the right mark.
3) Transfer the PCB to the second workstation.
4) Teach the left fiducial mark.
1: Fiducial mark for ST-Gate2
2: Fiducial mark for ST2F-Work
3: Placement point registered to the ST2F-Work
4: Placement Point registered to the ST-Gate2