OM-1012-001.pdf - 第129页
0305-001 Chapter 1 2-50 Tg0869-PM-OM

Procedure for Inversion (leftside right) of Tray Fixing Metal
When the tray fixing metal is used after the parts of the lever section
are rearranged, it must be re-labeled to avoid any mistake in determin-
ing the direction (right or left).
(1) Remove the screw fastening the lever to the base with a Phillips-type
screwdriver.
(2) Remove the screw fastening the spring to the base with a Phillips-type
screwdriver.
(3) Rearrange the direction of the lever.
(4) Fasten the lever to the base with the screw.
• Fasten the lever to “A” in Fig. A81 for MG-5050L.
• Fasten the lever to “B” in Fig. A81 for MG-5050R.
Fig. A81 Position where the lever and the spring should be fastened
(5) Fasten the spring to the base with the screw.
• Engage the spring with “C” in Fig. A81 for MG-5050L.
• Engage the spring with “D” in Fig. A81 for MG-5050R.
11.2 Tray Fixing Metals
0305-001 Chapter 1 2-49 Tg0869-PM-OM
A
C
D
B

0305-001 Chapter 1 2-50 Tg0869-PM-OM

0305-001 Chapter 1 3-1
Tg0869-PM-OM
Section 3
LINE Mode Menu