1-59 081 1-002 4.6 Cleaning of Linear Measure Sensor Periodically perform cleaning of the linear measure sensor to maintain reliable and stable measurement of component thickness. • Clean the sensor every day . • Change …

100%1 / 279
1-58
(7) Checktheoilllerportandwipeoldgreaseoutusinganapplicator.
Nipple
Fig 4A54-5
(8) Align the cutter unit with the origin position on the left.
Move it to the
origin position on the left.
(9) Attach the cover and fasten the four set screws.
(10) Attach the tape guid and fasten the four set screws.
(11) Attach the lower cover.
(12) Attach the upper cover.
(13) Lubricate the other cutter units using the same procedure in Steps (1) to (12).
4.5 Lubricating Procedure onto the Linear Guide Oil Filler Port
0811-002
1-59
0811-002
4.6 Cleaning of Linear Measure Sensor
Periodically perform cleaning of the linear measure sensor to maintain
reliable and stable measurement of component thickness.
Clean the sensor every day.
Change cleaning frequency according to varying frequency of use and
environmental conditions.
Linear Measure Sensor (Light Receiver)
Linear Measure Sensor
(Light Emitter)
Horizontal Direction
Conic Cap
Surface of Conic
Reflector
Linear Measure Sensor (Light Emitter)
Fig. 4A55
Whileyouarecleaningthe
lightemitter,thesurfaceoftheconicreector
must be cleaned softly and horizontally.
Notice
Cleaning it vertically may damage the conic cap.
When the conic cap is damaged, the component recognition might
not be made correctly.
CAUTION
The light emitter of the linear measure sensor is made of glass.
If the light emitter happens to be damaged, be sure to suck up
the fragments with a vacuum cleaner, etc.
Do not collect the fragments with your bare hands to protect
your hands from injuries.
4.6 Cleaning of Linear Measure Sensor
1-60
0712-002
4.6 Cleaning of Linear Measure Sensor
Preparation for Cleaning
(1) Lens Cleaning Cloth (Accessory)
(2) Cotton Swab
(3) Recommended Absolute Ethanol : C
2
H
6
O 99.5 vol/%
(High Purity)
Cleaning Procedure
(1) Press the [LINE MEAS] button on the "PERIODIC MAINT" submenu
bar. The "LINEAR MEASURE CLEANING" window appears.
(Operation Sequence: [MAINT] Button on Main Menu Bar →
[PERIODIC MAINT] Button on Submenu Bar → [LINE MEAS]
Button)
Fig. 4A56 "LINEAR MEASURE CLEANING" Window
(2) Select the head whose linear measure sensor should be cleaned.
(3) Press the [Nozzle Reset] button to store the vacuum nozzle in the nozzle
stocker (housing).
(4)
Press the [READY] switch of the pertinent stage.
The LED extinguishes.
The cover is unlocked.