3-20 0707-001 3.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 422318 Cnvr . Positioning1 Error The P .C.B was transported a predetermined distance, but the operation was not completed. There is a possibi…

100%1 / 279
3-190707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
422304 Cnvr. Positioning1 Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
422305 Cnvr. Positioning1 Error
The error was deected while the backup base was rising.
-----
422306 Cnvr. Positioning1 Error
The error was detected while the backup base was descending.
-----
422307 Cnvr. Positioning1 Error
Rise operation of a PCB stopper is not completed.
Please check a stopper.
422308 Cnvr. Positioning1 Error
Downward operation of a PCB stopper is not completed.
Please check a stopper.
422309 Cnvr. Positioning1 Error
The positioning change operation was not able to begin.
-----
422310 Cnvr. Positioning1 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the P.C.B on a conveyor
.
422311 Cnvr. Positioning1 Error
The reversal positioning operation was not able to begin.
-----
422312 Cnvr. Positioning1 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
422313 Cnvr
. Positioning1 Error
Pickup of a P.C.B went wrong.
Please check the existence of P.C.B or whether the support Jig has reached the
P.C.B.
422314 Cnvr
. Positioning1 Error
The pickup OFF of a P.C.B went wrong.
-----
422315 Cnvr. Positioning1 Error
Slowdown operation was not carried out at the time of carrying-in operation.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
422316
Cnvr. Positioning1 Error
Rise operation of a reversal PCB stopper is not completed.
Please check a stopper.
422317
Cnvr. Positioning1 Error
Downward operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
3-200707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
422318 Cnvr. Positioning1 Error
The P.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
422319 Cnvr. Positioning1 Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
422320 Cnvr. Positioning1 Error
The P.C.B. transfer operation could not start.
-----
422321 Cnvr. Positioning1 Error
An error was detected in transferring the P
.C.B..
Please continue the work after checking the P.C.B on a conveyor.
422322 Cnvr. Positioning1 Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B.
And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
422323 Cnvr
. Positioning1 Error
A servo error was found in the movement that the backup base was rising. The
backup jig and pins may be left under the transfer rail.
Cancel the error and perform zeroing operation after that, open the cover to
remove the left backup jig and pins under the transfer rail. Perform the setup
operation again to set the backup jig and the pins to the proper positions.
422324 Cnvr
. Positioning1 Error
Support pins /Jig were detected before the backup base starts to rise.
Remove the support pins / jig from the backup base. If the removing operation is
difficult, perform the function to move the support pin changing position.
423101 Input Cnvr. P.C.B. Overtime
The P.C.B. transport (carry in) from Cnvr. Positioning1 did not end in prescribed
time.
Please continue the work after checking the P
.C.B on a conveyor.
423102 Input Cnvr. P.C.B. Overtime
The P.C.B. transport (exhaust) to Cnvr
. Positioning1 did not end in prescribed
time.
Please continue the work after checking the P.C.B on a conveyor.
423103 Input Cnvr. P.C.B. Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor
.
423201 Input Cnvr. P.C.B. Detection
There are 2 P.C.B.'s around the inlet and the outlet on the conveyor.
Please continue the work after checking the P.C.B on a conveyor
.
3-210707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
423202 Input Cnvr. P.C.B. Detection
There is no P.C.B on the conveyer. After the P.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
423203 Input Cnvr. P.C.B. Detection
The conveyer entrance sensor detected P.C.B.
Please continue the work after checking the P.C.B on a conveyor.
423204 Input Cnvr. P.C.B. Detection
The P
.C.B was detected with the conveyer entrance sensor.
Please remove the P.C.B on a conveyor. Production can be continued.
423301 Input Cnvr. Error
The carrying in operation was not able to begin.
-----
423302 Input Cnvr. Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor
.
423303 Input Cnvr. Error
The exhaust operation was not able to begin.
-----
423304 Input Cnvr. Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor
.
423305 Input Cnvr. Error
The reversal positioning operation was not able to begin.
-----
423306 Input Cnvr. Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
423307 Input Cnvr. Error
The P
.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
423308 Input Cnvr
. Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
423309 Input Cnvr. Error
Speed reduction was not performed during P
.C.B. transfer operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P
.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424101 Cnvr. Positoining2 Overtime
The P.C.B. transport (carry in) from input cnvr. did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.