4OM-1429-008_w.pdf - 第179页
3-18 0712-002 3.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 422107 Cnvr . Positioning1 Overtime The reversal positioning operation did not end in prescribed time. Please continue the work after checkin…

3-170707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421316 Input Buffer Cnvr. Error
The P.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
421317 Input Buffer Cnvr. Error
Bar code information cannot be acquired definitely.
Please take out the P.C.B from a conveyer, and acquire bar code information
again.
421318 Input Buffer Cnvr
. Error
It detec
ted a Bo
ardAvailable signal in the state that a device cannot take in a P.C.B
from input.
Please get rid of the factor so that a BoardAvailable signal does not appear.
421319 Input Buffer Cnvr. Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
421320 Input Buffer Cnvr. Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
421321 Input Buffer Cnvr. Error
An error occurred during END P.C.B. transfer operation.
Put the P
.C.B. on the input conveyor and perform the "START". The product
operation can be continued that why the machine considers as if the P.C.B. put
was the end P.C.B..
422101 Cnvr
. Positioning1 Overtime
P.C.B. from inp. buffer cnvr. was not received.
Please continue the work after checking the P.C.B on a conveyor.
422102 Cnvr. Positioning1 Overtime
P
.C.B. moving to inp. buffer cnvr. was not received
Please continue the work after checking the P.C.B on a conveyor.
422103 Cnvr. Positioning1 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
422104 Cnvr. Positioning1 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
422105
Cnvr. Positioning1 Overtime
The P.C.B. transport (exhaust) to output cnvr. did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
422106 Cnvr
. Positioning1 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.

3-180712-002
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
422107 Cnvr. Positioning1 Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
422108 Cnvr. Positioning1 Overtime
The P.C.B. transfer operation could not be completed in time.
Please continue the work after checking the P.C.B on a conveyor.
422201 Cnvr. Positioning1 P.C.B. Detection
P.C.B.'s were at inlet and outlet of cnvr.
Please continue the work after checking the P.C.B on a conveyor.
422202 Cnvr. Positioning1 P.C.B. Detection
There is no P
.C.B on the conveyer. After the P
.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
422203 Cnvr. Positioning1 P
.C.B. Detection
No P.C.B. on the cnvr. After positioning released, P.C.B could not be detected.
Please continue the work after checking the P.C.B on a conveyor.
422204
Cnvr. Positioning1 P.C.B. Detection
The conveyer entrance sensor detected P.C.B.
Please continue the work after checking the P.C.B on a conveyor.
422205 Cnvr. Positioning1 P.C.B. Detection
The P
.C.B. that has not been positioned exists.
Please position the P.C.B.
422206 Cnvr. Positioning1 P.C.B. Detection
An unsuitable detected state of the sensor is being kept.
When you remove the factor which the sensor has detected and there is a
P.C.B in the way of carrying in, please return on input buffer cnvr. and resume
production by WarmStart.
422207
Cnvr. Positioning1 P.C.B. Detection
The P.C.B was unsuitable detected at the time of a carrying-in operation start.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
422208 Cnvr
. Positioning1 P.C.B. Detection
The P.C.B was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P
.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
422301 Cnvr. Positioning1 Error
The carrying in operation was not able to begin.
-----
422302 Cnvr. Positioning1 Error
The error was detected while carrying in was operating.
Please continue the work after checking the P
.C.B on a conveyor.
422303 Cnvr. Positioning1 Error
The exhaust operation was not able to begin.
-----

3-190707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
422304 Cnvr. Positioning1 Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
422305 Cnvr. Positioning1 Error
The error was deected while the backup base was rising.
-----
422306 Cnvr. Positioning1 Error
The error was detected while the backup base was descending.
-----
422307 Cnvr. Positioning1 Error
Rise operation of a PCB stopper is not completed.
Please check a stopper.
422308 Cnvr. Positioning1 Error
Downward operation of a PCB stopper is not completed.
Please check a stopper.
422309 Cnvr. Positioning1 Error
The positioning change operation was not able to begin.
-----
422310 Cnvr. Positioning1 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the P.C.B on a conveyor
.
422311 Cnvr. Positioning1 Error
The reversal positioning operation was not able to begin.
-----
422312 Cnvr. Positioning1 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
422313 Cnvr
. Positioning1 Error
Pickup of a P.C.B went wrong.
Please check the existence of P.C.B or whether the support Jig has reached the
P.C.B.
422314 Cnvr
. Positioning1 Error
The pickup OFF of a P.C.B went wrong.
-----
422315 Cnvr. Positioning1 Error
Slowdown operation was not carried out at the time of carrying-in operation.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
422316
Cnvr. Positioning1 Error
Rise operation of a reversal PCB stopper is not completed.
Please check a stopper.
422317
Cnvr. Positioning1 Error
Downward operation of a reversal PCB locate stopper is not completed.
Please check a stopper.