4OM-1429-008_w.pdf - 第206页
3-45 Erroe ID Error Name, Description, Cause, and Remedy 496801 Conveyor Width Automatic Setup (Input conveyor W2) An error occurred in the transfer driver comunications. (1) Check the communication cable. (2) Check the …

3-44
3.7 Automatic Setup
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
496606 Conveyor Width Automatic Setup (Input conveyor W2)
Voltage reduction on the power source was detected.
Check the transfer driver.
496607 Conveyor Width Automatic Setup (Input conveyor W2)
OT (+) was detected during auto operation.
Perform zeroing operation.
496608 Conveyor Width Automatic Setup (Input conveyor W2)
OT (-) was detected during auto operation.
Perform zeroing operation.
496717 Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (+) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496718 Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (-) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496727 Conveyor Width
Automatic Setup (Input conveyor W2)
An overrun sensor (+) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496728 Conveyor Width
Automatic Setup (Input conveyor W2)
An overrun sensor (-) was detected during input conveyor operation.
Perform the zeroing operation for the input conveyor.
496737
Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (+) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
496738 Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (-) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
4967
47 Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (+) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
4967
48 Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (-) was detected during positioning conveyor operation.
Perform the zeroing operation for the positioning conveyor.
496757
Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (+) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.
496758 Conveyor Width
Automatic Setup (Input conveyor W2)
An overrun sensor (-) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.
496767 Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (+) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor
.
496768 Conveyor Width Automatic Setup (Input conveyor W2)
An overrun sensor (-) was detected during output conveyor operation.
Perform the zeroing operation for the output conveyor.

3-45
Erroe ID Error Name, Description, Cause, and Remedy
496801 Conveyor Width Automatic Setup (Input conveyor W2)
An error occurred in the transfer driver comunications.
(1) Check the communication cable. (2) Check the power cable.
496802
-----
496803
-----
496804
-----
3.7
Automatic Setup
0712-002

3-46
3.8 Head-Related Errors
0707-001
3.8 Head-Related Errors
Table 4C9-1
Erroe ID Error Name, Description, Cause, and Remedy
4A0101 Head Zero Return
NL axis zeroing Error. Please confirm the nozzle has not fallen when
you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0102 Head Zero Return
HL axis zeroing Error. Please confirm the nozzle has not
fallen when
you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0103 Head Zero Return
L1 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0104 Head Zero Return
L2 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOTOR" screen.
4A0105 Head Zero Return
L3 axis zeroing Error. Please confirm the nozzle has not fallen when you push the
beam by the hand.
When the lock of a safety door cannot be canceled, please push an emergency
stop button. (Please confirm the nozzle has not fallen when you push the beam
by the hand.) Please check error on a "MAINT-DVC CHK- MOT