4OM-1429-008_w.pdf - 第220页
3-59 3.10 Pickup Error 0712-002 3.10 Pickup Error T able 4C1 1 Erroe ID Error Name, Description, Cause, and Remedy 500101 Comp. Missing (Sensor) There is a possibility that the picked comps. have fallen on the feeder and…

3-58
3.9 Others
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
4b2903 Linear Scale Error
An error for the linear scale position occurred at the beam Y-axis (rear) during
zeroing operation.
(1) Check the linear scale on the beam Y-axis (rear).
(2) Check the linear scale attaching position on the Y1 and Y2.
(3) Check if the process of the linear scale origin mark on the Y1 and Y2 has an
error.
4b2904 Linear Scale Error
An error for the linear scale position occurred at the beam Y-axis (front) during
zeroing operation.
(1) Check the linear scale on the beam Y
-axis (front).
(2) Check the linear scale attaching position on the Y1 and
Y2.
(3) Check if the process of the linear scale origin mark on the Y1 and Y2 has an
error.
4b2905 Linear Scale Error
An error for the linear scale skip occurred at the beam Y-axis (rear) during zeroing
operation.
Please confirm if the linear scale on the beam Y
-axis (rear) has flaws and soil.
4b2906 Linear Scale Error
An error for the linear scale skip occurred at the beam Y
-axis (front) during
zeroing operation.
Please confirm if the linear scale on the beam Y-axis (front) has flaws and soil.
4b2907 Linear Scale Error
An error for the linear scale parallel offset deviation occurred at the beam Y-axis
(rear) during zeroing operation.
Please check the linear scale attaching condition on the beam Y-axis (rear).
4b2908
Linear Scale Error
An error for the linear scale parallel offset deviation occurred at the beam Y-axis
(front) during zeroing operation.
Please check the linear scale attaching condition on the beam Y-axis (front).
4b2c01
Error in communications between CPU
Failed in communications with the STG.#1 control CPU.
-----
4b2c02 Error in communications between CPU
Failed in communications with the STG.#2 control CPU.
-----
4b2c03 Error in communications between CPU
Failed in communications with the Recog. CPU.
-----
4b2c04 Error in communications between CPU
Failed in communications with the Control CPU.
-----

3-59
3.10 Pickup Error
0712-002
3.10 Pickup Error
Table 4C11
Erroe ID Error Name, Description, Cause, and Remedy
500101 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500102 Comp. Missing (Sensor)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500201 Vacuum Sensor Error
-----
500301 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500302 Comp. Missing (Recog)
There is a possibility that the picked comps. have fallen on the feeder and please
confirm it.
500401 Comp. Recog Error
-----
500501 Shortage of Component
Shortage of Component
-----
500502 Feeder Reload Stop
Feeder Reload Stop (Splicing)
-----
500601 V
.Bend Detection Error
-----
500701 Shortage of Component (Alternated Feeder)
-----
500a01 Auto Recovery Pause
Attach the new comp. And press [READY]. Then, press [START] button to re-
start.
-----
500a02 Auto Recovery Pause
Quick recovery stop
-----

3-60
3.10 Pickup Error
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
500c01 Comp. Vertical(Sensor)
-----
500d01 Comp. Missing (Sensor) After Chuck
-----
500e01 Comp. Missing (Sensor) Befor Mount
-----
500f01 Comp. Thickness(Sensor)
-----
501001
-----