4OM-1429-008_w.pdf - 第198页
3-37 3.7 Automatic Setup 0707-001 Erroe ID Error Name, Description, Cause, and Remedy 49060e Conveyor Width Automatic Adjustment The L2 axis was not zeroed successfully . ----- 49060f Conveyor Width Automatic Adjustment …

3-36
3.7 Automatic Setup
0707-001
3.7 Automatic Setup
Table 4C9
Erroe ID Error Name, Description, Cause, and Remedy
490601 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L1 axis might
be located lower than the pass line.
-----
490602 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L2 axis might
be located lower than the pass line.
-----
490603 Conveyor Width Automatic Adjustment
A P.C.B. exists on the L conveyor.
-----
490604 Conveyor Width Automatic
Adjustment
A P.C.B. exists on the R conveyor.
-----
490605 Conveyor Width
Automatic Adjustment
A P.C.B. exists on the R conveyor
.
-----
490606 Conveyor Width Automatic Adjustment
The PWC axis for conveyor width adjustment cannot be driven. The L axis might
be located lower than the pass line.
-----
490607
Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed.
-----
490608 Conveyor Width Automatic Adjustment
An error occurred in the PWC axis while the conveyor width was being changed.
-----
490609
Conveyor Width Automatic Adjustment
The PWC axis is not zeroed completely.
-----
49060a Conveyor Width Automatic
Adjustment
An error occurred in the PWC axis while the conveyor width was being changed
through an smooth inching operation.
-----
49060b Conveyor Width Automatic Adjustment
The current position of the L1 axis is not managed because the axis is not zeroed.
-----
4906
0c Conveyor Width Automatic
Adjustment
The current position of the L2 axis is not managed because the axis is not zeroed.
-----
49060d Conveyor Width
Automatic Adjustment
The L1 axis was not zeroed successfully.
-----

3-37
3.7 Automatic Setup
0707-001
Erroe ID Error Name, Description, Cause, and Remedy
49060e Conveyor Width Automatic Adjustment
The L2 axis was not zeroed successfully.
-----
49060f Conveyor Width Automatic Adjustment
The BPC axis was not zeroed successfully.
-----
490610 Conveyor Width Automatic Adjustment
The cu
rrent
posi
tion of the X1 axis is not managed because the axis is not zeroed.
-----
490611 Conveyor Width Automatic Adjustment
The current posit
ion of the X2 axis is not managed because the axis is not zeroed.
-----
490612 Conveyor Width Automatic Adjustment
The current position of the Y axis is not managed because the axis is not zeroed.
-----
490613 Conveyor Width Automatic Adjustment
The escape operation of the X axis ended in an error condition.
-----
490614 Conveyor Width Automatic Adjustment
The escape operation of the Y axis ended in an error condition.
-----
490615 Conveyor Width Automatic
Adjustment
The support pins could not ascend because the maximum conveyor width was not
obtained.
-----
490616 Conveyor Width Automatic Adjustment
The current P
.C.B. width was not obtained because the pattern program data is
not defined.
-----
490617 Conveyor Width Automatic Adjustment
Software limit
-----
490618
Conveyor Width Automatic Adjustment
There is a P.C.B. on the conveyor
-----
490619 Conveyor Width Automatic
Adjustment
Failed in Program Change Operation(Data Error).
-----
49061a Conveyor Width Automatic Adjustment
Failed in Program Change Operation(Time out).
-----
49061b
Conveyor Width Automatic Adjustment
Backup Base zeroing Error.
-----

3-380707-001
3.7 Automatic Setup
Erroe ID Error Name, Description, Cause, and Remedy
49061c Conveyor Width Automatic Adjustment
Head Up/Down Axis Zeroing Error.
-----
49061d Conveyor Width Automatic Adjustment
The P.C.B was detected on the Input conveyor.
Please remove the P.C.B on a Input conveyor.
49061e Conveyor Width Automatic Adjustment
The P.C.B was detected on the Cnvr. Positioning1.
Please remove the P.C.B on a Cnvr
. Positioning1.
49061f Conveyor Width Automatic Adjustment
The P.C.B was detected on the central conveyor
.
Please remove the P.C.B on a central conveyor.
490620 Conveyor Width Automatic Adjustment
The P.C.B was detected on the Cnvr
. Positioning2.
Please remove the P.C.B on a Cnvr. Positioning2.
490621 Conveyor Width Automatic Adjustment
The P.C.B was detected on the Output conveyor
.
Please remove the P.C.B on a Output conveyor.
490690 Conveyor Width Automatic Adjustment
Auto Setup Error(Others).
-----
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702
Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490704 Nozzle set up
Nozzle Stocker up/dowon failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490705 Nozzle set up
An error occurred with the nozzle existence check in the stocker before the nozzle
is placed.
Please check whether there is any dif
ference in stocker arrangement data and
real arrangement.
490706
Nozzle set up
Head nozzle existence confirmation has error.
Please check whether there is any difference in head arrangement data and real
arrangement.