4OM-1429-008_w.pdf - 第228页
3-67 3.12 Automatic T eaching 0712-001 Erroe ID Error Name, Description, Cause, and Remedy 601a01 Linear measure correction re-teach The linear measure reading is abnormal. Please confirm whether the nozzle has adhered to…

3-66
3.12 Automatic Teaching
0712-001
Erroe ID Error Name, Description, Cause, and Remedy
600801 Feeder offset(A) teach
Please push the Feeder Ready SW
-----
600802 Feeder offset(A) teach
Feeder recog Mark Error
Manual Alignment
600803 Feeder offset(A) teach
Feeder connection is set in test mode.
-----
600804 Feeder offset(A) teach
The data of the feeder was not able to be read.
-----
600805 Feeder offset(A) teach
Feeder recog. Process time over
-----
600901 Feeder offset(B) teach
-----
601000 Master nozzle level offset teach
-----
601101 Nozzle level of
fset teach
The nozzle level instruction result exceeded the tolerance.
-----
601200 Y Axis of
fset teach
-----
601301 Nozzle stocker offset teaching
Stocker Mark #1 Recognition Error
Please select "Mnl Align Mark1" and adjust the manual.
601302 Nozzle stocker offset teaching
Stocker Mark #2 Recognition Error
Please select "Mnl Align Mark2" and adjust the manual.
601400 Msater nozzle level offset teach
-----
601501 Recog camera light teach
Recog Process error
-----
601601 Comp. Recog. Camera magnifi
cation teach.
Recog Process error
-----

3-67
3.12 Automatic Teaching
0712-001
Erroe ID Error Name, Description, Cause, and Remedy
601a01 Linear measure correction re-teach
The linear measure reading is abnormal.
Please confirm whether the nozzle has adhered to the position.
601a02 Linear measure correction re-teach
Offset correction can not be completed. Please use the big nozzle(HA05) teach
again and adjust the light & receive optical Axis
-----
601a03 Linear measure correction re-teach
Nozzle can not be detected.
-----
601a04 Linear measure correction re-teach
The linear measure control has an error.
-----
601a05 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R)
-----
601a06 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/NR)
-----
601a07 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Sample
All E/R & E/NR detection error)
-----
601a08 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error:
Shortage of Samples)
-----
601a09 Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Failed
in the generation of the correction formula.)
-----
601a0a Linear measure correction re-teach
The correction value could not be created. Re-teach it with a thick nozzle (HA05),
otherwise adjust the emitting and receiving optical-axis. (Correction Error: Inside
accuracy check error)
-----
601b01 Automatic teaching
The nozzle is not installed.
Please install the nozzle.

3-68
3.13 Test
0712-001
3.13 Test
Table 4C14
Erroe ID Error Name, Description, Cause, and Remedy
610101 Comp Recog Test
The nozzle type data doesn't exist.
-----
610102 Comp Recog Test
-----
610103 Comp Recog Test
-----
610104 Comp Recog Test
-----
610105 Comp Recog Test
-----
610106 Comp Recog Test
-----
610107
Comp Recog Test
-----
610108
Comp Recog Test
-----
610109
Comp Recog Test
-----
610201
XY Beam T
est
-----
610301 P.E.C Recog
Test
-----
610401 P
.E.C Recog Test
-----
610501
P.E.C Recog T
est
-----