4OM-1429-008_w.pdf - 第169页
3-8 0712-002 3. Error IDs and Remedial Procedures Erroe ID Error Name, Description, Cause, and Remedy 400706 Zero Return The Basis Mark recognition processing at the time of a beam XY (rear) starting zeroed was not compl…

3-70712-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400431 Interlock Error
A pickup-failed component (Front) were detected. [DB-B0510]
Open the safety cover and remove the failed component in the pickup operation
after that, execute the Warm start.
400501 Lightning Surge Warning
Lightning Surge Protector works; L201,L202,L203. Please turn on the load power
supply after resetting error.
-----
400502 Lightning Surge Warning
-----
400503 Lightning Surge Warning
-----
400504 Lightning Surge Warning
-----
400505 Lightning Surge Warning
-----
400601 Servo Alarm
Servo Alarm Detected
-----
400602
Servo Alarm
All Beam alarm reseting API Error
-----
400701 Zero Return
Beam XY zeroing Error
-----
400702
Zero Return
When beam XY (Rear) starting zeroed, the standard mark gap was generated.
Please start up the power supply.
400703 Zero Return
When beam XY (Front) starting zeroed, the standard mark gap was generated.
Please start up the power supply.
400704 Zero Return
When beam XY (Rear) starting zeroed, recognition error of a standard mark was
generated.
-----
400705 Zero Return
When beam XY (Front) starting zeroed, recognition error of a standard mark was
generated.
-----

3-80712-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400706 Zero Return
The Basis Mark recognition processing at the time of a beam XY (rear) starting
zeroed was not completed within predetermined time.
-----
400707 Zero Return
The Basis Mark recognition processing at the time of a beam XY (front) starting
zeroed was not completed within predetermined time.
-----
400801 Cutter Error
Cutter Alarm Detected(waveform Data setting)
-----
400802 Cutter Error
Cutter Alarm Detected(Zeroing)
-----
400803 Cutter Error
Cutter axis Time Out(Start zero)
-----
400804
Cutter Error
Cutter axis Time Out(Zero)
-----
400805 Cutter Error
Cutter axis zero finished
-----
400806 Cutter Error
Cutter axis Alarm Detection(Start Locating)
-----
400836 Cutter Error
Cutter axis Time Out(when locating)
-----
400837 Cutter Error
Cutter axis Alarm Detected(During Locating)
-----
400838 Cutter Error
Cutter axis Alarm Detected(During Locating). The cutter axis zeroing was carried
out.
Please check whether there are any errors in a cutter unit.
400839 Cutter Error
Because main circuit of the cutter axis was OFF or the servo wa
s OFF. The feeder
base descent operation was not able to be done.
Please confi
rm the emergency stop and the safety door.
400901 Tray Interlock Error
Main Power Off
-----
400902 T
ray Interlock Error
-----

3-90712-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400903 Tray Interlock Error
-----
400904 Tray Interlock Error
-----
400905 T
ray Interlock Error
-----
400a01 Head Interlock Error
Head excess pushing detection 3[B05]
-----
400a02 Head Interlock Error
Head excess pushing detection 2[B05]
-----
400a03 Head Interlock Error
Head excess pushing detection 1[B05]
-----
400a04 Head Interlock Error
Pass line detection 3[B04]
-----
400a05 Head Interlock Error
Pass line detection 2[B04]
-----
400a06 Head Interlock Error
Pass line detection 1[B04]
-----
400a07 Head Interlock Error
Head Stop
-----
400a08 Head Interlock Error
Releasing the brake is impossible during Servo On.
-----
400a09 Head Interlock Error
Nozzle tilting detection 1[B161
1]
Please confirm the nozzle in the Nozzle Stocker 1.
400a0a Head Interlock Error
Nozzle tilting detection 2[B161
1]
Please confirm the nozzle in the Nozzle Stocker 2.
400b01 Feeder preparation complete
A
wrong setting of the suppressor or disengaged Latch was detected. [DA-B0510]
Open the safety cover and confirm that there is no interference with the head, and
then, release the ready feeder.
400c01 Nozzle stocker down time out
Nozzle stock unit lower bound detection 1 was not turned on in prescribed time.
Please confi
rm the lower bound detection 1 sensor of nozzle stock unit.