4OM-1429-008_w.pdf - 第171页
3-10 0712-002 3. Error IDs and Remedial Procedures Erroe ID Error Name, Description, Cause, and Remedy 400c02 Nozzle stocker down time out Nozzle stock unit lower bound detection 2 was not turned on in prescribed time. P…

3-90712-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400903 Tray Interlock Error
-----
400904 Tray Interlock Error
-----
400905 T
ray Interlock Error
-----
400a01 Head Interlock Error
Head excess pushing detection 3[B05]
-----
400a02 Head Interlock Error
Head excess pushing detection 2[B05]
-----
400a03 Head Interlock Error
Head excess pushing detection 1[B05]
-----
400a04 Head Interlock Error
Pass line detection 3[B04]
-----
400a05 Head Interlock Error
Pass line detection 2[B04]
-----
400a06 Head Interlock Error
Pass line detection 1[B04]
-----
400a07 Head Interlock Error
Head Stop
-----
400a08 Head Interlock Error
Releasing the brake is impossible during Servo On.
-----
400a09 Head Interlock Error
Nozzle tilting detection 1[B161
1]
Please confirm the nozzle in the Nozzle Stocker 1.
400a0a Head Interlock Error
Nozzle tilting detection 2[B161
1]
Please confirm the nozzle in the Nozzle Stocker 2.
400b01 Feeder preparation complete
A
wrong setting of the suppressor or disengaged Latch was detected. [DA-B0510]
Open the safety cover and confirm that there is no interference with the head, and
then, release the ready feeder.
400c01 Nozzle stocker down time out
Nozzle stock unit lower bound detection 1 was not turned on in prescribed time.
Please confi
rm the lower bound detection 1 sensor of nozzle stock unit.

3-100712-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400c02 Nozzle stocker down time out
Nozzle stock unit lower bound detection 2 was not turned on in prescribed time.
Please confirm the lower bound detection 2 sensor of nozzle stock unit.
400c03 Nozzle stocker down time out
Nozzle stock unit lower bound detection 3 was not turned on in prescribed time.
Please confirm the lower bound detection 3 sensor of nozzle stock unit.
400c04 Nozzle stocker down time out
Nozzle stock unit lower bound detection 4 was not turned on in prescribed time.
Please confirm the lower bound detection 4 sensor of nozzle stock unit.
400d01 Software Interlock Error
Head (rear) NL axis's poor operation was detected, and the scram of the XY axis
was carried out.
Please perform a zeroing.
400d02 Software Interlock Error
Head (rear) NL axis's poor operation was detected, and the scram of the XY axis
was carried out.
Please perform a zeroing.

3-110707-001
3.2 Data
3.2 Data
Table 4C4
Erroe ID Error Name, Description, Cause, and Remedy
410101 Data Error
Machine data and system data error detected.
-----
410102 Data Error
Auto run start mode setup data error
-----
410103 Data Error
Steps in converted pattern program is more
-----
410104 Data Error
Pattern Program Errors(P
.E.C.Recog step error)
-----
410105 Data Error
The component library data used by the pattern program data doesn't exist.
-----
410106 Data Error
The nozzle type data registered in the nozzle data doesn't exist
-----
410107 Data Error
The nozzle type data registered in the nozzle data doesn't exist
-----
410201 Mode data Error
Abnormality is found in the production driving beginning mode setting data.
-----
410301 Pattern Program Error
Steps in converted pattern program is more
-----
410302 Pattern Program Error
There are Errors in converted pattern program(P
.E..C. recog steps Error.)
-----
410303 Pattern Program Error
The converted pattern program is not exist, the data is damaged.
-----
410304 Pattern Program Error
The error is found in the adsorption nozzle number of the conversion pattern
program.
-----
410305 Pattern Program Error
The error is found in the order of adsorption of the conversion system pattern
program.
-----