4OM-1429-008_w.pdf - 第216页

3-55 3.9 Others 0712-002 Erroe ID Error Name, Description, Cause, and Remedy 4b230c Feeder (Servo Error) Alarm Code:Ad - Excessive deviation in position If the error occurs frequently , replace the feeder . (It may be ca…

100%1 / 279
3-54
3.9 Others
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
4b2302 Feeder (Servo Error)
Alarm Code:A1 - Ov
er Current Error (Foreign substances in the tape feeding drive
section)
Confirm whether or not the tape is being jammed on the path./ Confirm the reel to
operate smoothly./ Confirm whether or not some components and dust are being
caught in the sprocket./ Confirm whether or not some components and dust are
being caught in the tape feeding gear.
4b2303 Feeder (Servo Error)
Alarm Code:A2 - Others
-----
4b2304 Feeder (Servo Error)
Alarm Code:A3 - Others
-----
4b2305 Feeder (Servo Error)
Alarm Code:A4 - Ma
in Circuit Power Supply Error (Please check the power supply
voltage.) (G04)
Please check the power supply voltage.
4b2306 Feeder (Servo Error)
Alarm Code:A5 - Fault Speed Error (Tape catching)
Confirm whether or not the tape is being jammed on the path./ Confirm the reel to
operate smoothly./ Confirm whether or not some components and dust are being
caught in the sprocket./ Confirm whether or not some components and dust are
being caught in the tape feeding gear.
4b2307 Feeder (Servo Error)
Alarm Code:A6 - Others
-----
4b2308 Feeder (Servo Error)
Alarm Code:A7 - Fault Load Error (Tape twisting, Catching foreign substances)
Confirm whether or not the tape is being jammed on the path./ Confirm the reel to
operate smoothly./ Confirm whether or not some components and dust are being
caught in the sprocket./ Confirm whether or not some components and dust are
being caught in the tape feeding gear.
4b2309 Feeder (Servo Error)
Alarm Code:A8 - Encoder Error (Breaking wire, Breakdown of control P.C.B. and
Defective servo motor)
Please replace the feeder.
4b230a Feeder (Servo Error)
Alarm Code:Ab - System Error
Please replace the feeder
. (It may be caused by trouble of the control P.C.B..)
4b230b Feeder (Servo Error)
Alarm Code:Ac - Reckless Run Detection Error
Please replace the feeder. (It may be caused by trouble of the control P.C.B..)
3-55
3.9 Others
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
4b230c Feeder (Servo Error)
Alarm Code:Ad - Excessive deviation in position
If the error occurs frequently, replace the feeder. (It may be caused by trouble of
the control P.C.B..)
4b2401 Feeder (Movement Error)
Alarm Code:E0 -
(1) Damaged cover tape/ (2) Cover tape jammed in the storage/ (3) Splicing
section peeling off
(1)
Confirm whether or not the cover tape is set correctly/
(2)
Please remove the cover tape from the storage section./
(3)
Please check the splicing condition if the work performed correctly in the
process.
4b2402 Feeder (Movement Error)
Alarm Code:E1 - Cover tape peeling off error (Get caught up)
(1) Confirm whether or not the cover tape is set correctly.
(2) Confirm whether or not some stickum has adhered to the suppressor.
(3) Confirm the splicing condition if the work performed correctly in the process.
4b2403 Feeder (Movement Error)
Alarm Code:E2 - Origin Position Checking Error (Excessively out of the origin
during servo ON)
If the error occurs frequently, replace the feeder. (It may be caused by trouble of
the control P.C.B..)
4b2405 Feeder (Movement Error)
Alarm Code:E4 - Positioning Completion Timeout (Foreign substances in the
sprocket wheel)
Confirm whether or not the tape is being jammed on the path./ Confi
rm the reel to
operate smoothly./ Confirm whether or not some components and dust are being
caught in the sprocket.
4b2406 Feeder (Movement Error)
Alarm Code:E5 - Redundant Order Error
-----
4b2407 Feeder (Movement Error)
Alarm Code:E6 - Lane Change Timeout Error
If the error occurs frequently, replace the feeder. (It may be caused by trouble of
the control P.C.B..)
4b2408 Feeder (Movement Error)
Alarm Code:E7 - Servo ON
Timeout
If the error occurs frequently, replace the feeder. (It may be caused by trouble of
the control P
.C.B..)
4b2410 Feeder (Movement Error)
A pickup error occurred due to feeder operation problem. Please check the feeder
and the component.
-----
3-56
3.9 Others
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
4b2411 Feeder (Movement Error)
Alarm Code:E5 - Redundant Order Error (A feeding error may occur.)
Confirm whether or not the tape is being jammed on the path./ Confirm the reel to
operate smoothly./ Confirm whether or not some components and dust are being
caught in the sprocket./ Confirm whether or not some components and dust are
being caught in the tape feeding gear.
4b2421 Feeder (Movement Error)
Alarm Code: E0 - Deviated origin position of the belt transfer servo motor axis.
Check whether or not the shield plate position attached to the belt transfer servo
motor axis deviated.
4b2422 Feeder (Movement Error)
Alarm Code:E1 - RS section Driving Error
Check whether or not dust adheres to the sensor position of the PS unit startup
trigger.
4b2425 Feeder (Movement Error)
Alarm Code:E4 - Positioning Completion Timeout
Check whether or not foreign particles get into the servo motor timing belt and
worm axis /worm wheel sections.
4b2426 Feeder (Movement Error)
Alarm Code:E5 - Redundant Order Error
-----
4b2427 Feeder (Movement Error)
Alarm Code:E6 - Timeout Error in Changing Servo Motor
Axis.
-----
4b2428 Feeder (Movement Error)
Alarm Code:E7 - Servo ON Timeout
-----
4b2501 Failed Splicing Operation
Alarm Code:E3 - (1)No supplied history/ (2)Dirty splicing detection sensor (dust
adhesion)
(1) Please operate to resupply components in the machine after splicing
operation.
(2) Please clean the joint detection sensor.
4b2601 Unit P.C.B. B.B.R. Information
There is no information in the relevant P.C.B. (on the
Transfer Conveyor).
Delete the BBR information after removing the P.C.B..
4b2602 Unit P
.C.B. B.B.R. Information
There is no information in the relevant P.C.B. (on the Transfer XY
-Table).
Delete the BBR information after removing the P.C.B..
4b2603 Unit P.C.B. B.B.R. Information
A problem was found in the unit PCB BBR information.
Delete the BBR information after removing the P.C.B..
4b2701
Start Process(Feeder Connect Error)
A special feeder is appointed. Please confirm the model of a set feeder.
-----