3-22 0712-002 3.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 424102 Cnvr . Positoining2 Overtime The P .C.B. transport (exhaust) to output cnvr . did not end in prescribed time. Please continue the work…

100%1 / 279
3-210707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
423202 Input Cnvr. P.C.B. Detection
There is no P.C.B on the conveyer. After the P.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
423203 Input Cnvr. P.C.B. Detection
The conveyer entrance sensor detected P.C.B.
Please continue the work after checking the P.C.B on a conveyor.
423204 Input Cnvr. P.C.B. Detection
The P
.C.B was detected with the conveyer entrance sensor.
Please remove the P.C.B on a conveyor. Production can be continued.
423301 Input Cnvr. Error
The carrying in operation was not able to begin.
-----
423302 Input Cnvr. Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor
.
423303 Input Cnvr. Error
The exhaust operation was not able to begin.
-----
423304 Input Cnvr. Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor
.
423305 Input Cnvr. Error
The reversal positioning operation was not able to begin.
-----
423306 Input Cnvr. Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
423307 Input Cnvr. Error
The P
.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
423308 Input Cnvr
. Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
423309 Input Cnvr. Error
Speed reduction was not performed during P
.C.B. transfer operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P
.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424101 Cnvr. Positoining2 Overtime
The P.C.B. transport (carry in) from input cnvr. did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
3-220712-002
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
424102 Cnvr. Positoining2 Overtime
The P.C.B. transport (exhaust) to output cnvr. did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
424103 Cnvr. Positoining2 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
424104 Cnvr. Positoining2 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
424106 Cnvr. Positoining2 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
424107 Cnvr. Positoining2 Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
42410
8 Cnvr. Positoining2 Overtime
The P.C.B. transfer operation could not be completed in time.
Please continue the work after checking the P.C.B on a conveyor.
424201 Cnvr. Positioning2 P.C.B. Detection
P.C.B.'s were at inlet and outlet of cnvr.
Please continue the work after checking the P
.C.B on a conveyor.
424202 Cnvr. Positioning2 P
.C.B. Detection
There is no P.C.B on the conveyer. After the P
.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
424203 Cnvr. Positioning2 P
.C.B. Detection
No P.C.B. on the cnvr. After positioning released, P.C.B could not be detected.
Please continue the work after checking the P.C.B on a conveyor.
424204
Cnvr. Positioning2 P.C.B. Detection
The conveyer entrance sensor detected P.C.B.
Please continue the work after checking the P.C.B on a conveyor.
424205 Cnvr. Positioning2 P.C.B. Detection
The P
.C.B. that has not been positioned exists.
Please position the P.C.B.
424206 Cnvr. Positioning2 P.C.B. Detection
An unsuitable detected state of the sensor is being kept.
When you remove the factor which the sensor has detected and there is a
P.C.B in the way of carrying in, please return on input buffer cnvr. and resume
production by WarmStart.
424207
Cnvr. Positioning2 P.C.B. Detection
The P.C.B was unsuitable detected at the time of a carrying-in operation start.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
3-23
3.3 Conveyor
0707-001
Erroe ID Error Name, Description, Cause, and Remedy
424208 Cnvr. Positioning2 P.C.B. Detection
The P.C.B was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424301 Cnvr. Positioning2 Error
The carrying in operation was not able to begin.
-----
424302 Cnvr. Positioning2 Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor.
424303 Cnvr. Positioning2 Error
The exhaust operation was not able to begin.
-----
424304 Cnvr
. Positioning2 Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
424305 Cnvr. Positioning2 Error
The error was detected while the backup base was rising.
-----
424306 Cnvr. Positioning2 Error
The error was detected while the backup base was descending.
-----
424307 Cnvr. Positioning2 Error
Rise operation of a PCB stopper is not completed.
Please check a stopper.
424308 Cnvr. Positioning2 Error
Downward operation of a PCB stopper is not completed.
Please check a stopper
.
424309 Cnvr. Positioning2 Error
The positioning change operation was not able to begin.
-----
424310 Cnvr. Positioning2 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the P.C.B on a conveyor
.
424311 Cnvr. Positioning2 Error
The reversal positioning operation was not able to begin.
-----
424312 Cnvr. Positioning2 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
424313 Cnvr
. Positioning2 Error
Pickup of a P.C.B went wrong.
Please check the existence of P.C.B or whether the support Jig has reached the
P.C.B.