4OM-1429-008_w.pdf - 第211页
3-50 3.9 Others 0712-002 Erroe ID Error Name, Description, Cause, and Remedy 4b0d01 Serial Out Mode Error There was no response to the Serial Out Mode. ----- 4b0d02 Serial Out Mode Error Communication failed to Shtg. of …

3-49
3.9 Others
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
4b0601 Auto Run Start Error
Production operation has not started within predetermined time. (Please push a
start button again)
-----
4b0701 Communication Timeout
Communication failed to STG.#1 CPU
-----
4b0702 Communication Timeout
Communication failed to STG.#2 CPU
-----
4b0703 Communication Timeout
Communication failed to Recog. CPU
-----
4b0704 Communication Timeout
Communication failed to STG CPU
-----
4b0801 Linear measure operation is abnormal.
Linear measure was found abnormality while measuring.
-----
4b0802 Linear measure operation error
The measurement by the linear measure sensor was not completed on time.
-----
4b0803 Linear measure operation error
There is a problem in the values measured by the linear measure sensor.
-----
4b0901 Firmware Updating
T
imeout
Firmware update did not end in prescribed time.
-----
4b0a01 Feeder Alarm
Feeder
Alarm. Please confirm the feeder and the component.
-----
4b0b01 Feeder base-main body connector unconnection
The connector on the feeder base-main body was disconnected. [B0916]
Please connect the connector on the feeder base to the main body, and press the
stage leady SW
.
4b0c01 Nozzle Confirmation Error before pick up comp
Abandonment is stopped because comp. had been detected on the nozzle.
Please check placement state on placement step recovery screen.
4b0c02
Nozzle Confirmation Error before pick up comp
Residual components were found in the nozzle while production operation.
Please confirm whether there is an error in the P.C.B.
4b0c03 Nozzle Confirmation Error before pick up comp
Abandonment is stopped because comp. had been detected on the nozzle.
Please confirm and clean up the nozzle if this error continues.

3-50
3.9 Others
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
4b0d01 Serial Out Mode Error
There was no response to the Serial Out Mode.
-----
4b0d02 Serial Out Mode Error
Communication failed to Shtg. of Comp. Host.
-----
4b0d03 Nozzle Confirmation Error before pick up comp
Communication with the Shtg. of Comp. Host has error.
-----
4b0e01 Splicing tape set error
The joint part of splicing tape is not correctly set. Please extract a feeder and
check whether the tape has separated from the guide.
-----
4b0f01 Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of feeder adsorption.
-----
4b0f02 Decreasing of Comp. Hdlg. Rate
It stopped automatically by the rate fall of nozzle adsorption.
-----
4b1
101
Conveyance aging
Abnormalities occurred during P.C.B conveyance axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-L
axis, NA-L
axis, NB-L axis, NC-L axis, NR-L axis).
4b1102 Conveyance aging
The timeout occurred in conveyance axis operation during P.C.B conveyance axis
aging.
Please check motor, amplifier and unusual contents of servo. (NL-L axis, NA-L
axis, NB-L
axis, NC-L axis, NR-L axis).
4b1103
Conveyance aging
Abnormalities occurred during backup base axis aging.
Please check motor, amplifier and unusual contents of servo. (NA-B axis, NC-B
axis).
4b1104 Conveyance aging
The timeout occurred in backup base axis operation during backup base axis
aging.
Please check motor, amplifier and unusual contents of servo. (NA-B axis, NC-B
axis).
4b1105 Conveyance aging
Abnormalities occurred during Y arrangement shuttle axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-W1 axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).
4b1
106 Conveyance aging
The timeout occurred in Y arrangement shuttle axis operation during Y
arrangement shuttle axis aging.
Please check motor, amplifier and unusual contents of servo. (NL-W1 axis,
NL-W2 axis, NR-W1 axis, NR-W2 axis).

3-51
3.9 Others
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
4b1201 Press in error / Insertion error
There is an error with the component pressed in or Insertion
Open safety cover and confirm the component on P.C.B. Please remove it or
revise it
4b1901 Monoaxial zeroing is abnormal.
It detected abnormality during movement.
Please get rid of an abnormal factor
4b1902 Monoaxial zeroing is abnormal.
It is impossible of W2 axis zeroing.
Please perform W1 axis zeroing.
4b1a01 Process error
Failed in restoration of the Machine data.
Please execute restoration operation from NT again.
4b1a02 Process error
Failed in restoration of the Network data.
Please confirm the network setting.
4b1a03 Process error
Failed in data transfer.
Please reboot machine.
4b2001 P.C.B Height Measurement
Abnormal measured value was detected.
Check the measurement position.
4b2002 P.C.B Height Measurement
Abnormality occurred for communication with a sensor
-----
4b2003 P.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
Running is stopped.
-----
4b2004 P
.C.B Height Measurement
The abnormality number of times of measured value was beyond a set point.
-----
4b2005 P.C.B Height Measurement
A measurement result is abnormal(measure in arbitrary position)
Check the measurement position.
4b2006
P.C.B Height Measurement
Surpass a measurement range. (+ direction)
-----
4b2007 P.C.B Height Measurement
Surpass a measurement range. (- direction)
-----
4b2008 P.C.B Height Measurement
Detected a curve more than permission values. (+ direction)
-----