3-23 3.3 Conveyor 0707-001 Erroe ID Error Name, Description, Cause, and Remedy 424208 Cnvr . Positioning2 P .C.B. Detection The P .C.B was detected with the conveyer entrance sensor . Please return the P .C.B. to the pro…

100%1 / 279
3-220712-002
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
424102 Cnvr. Positoining2 Overtime
The P.C.B. transport (exhaust) to output cnvr. did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
424103 Cnvr. Positoining2 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
424104 Cnvr. Positoining2 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
424106 Cnvr. Positoining2 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
424107 Cnvr. Positoining2 Overtime
The reversal positioning operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
42410
8 Cnvr. Positoining2 Overtime
The P.C.B. transfer operation could not be completed in time.
Please continue the work after checking the P.C.B on a conveyor.
424201 Cnvr. Positioning2 P.C.B. Detection
P.C.B.'s were at inlet and outlet of cnvr.
Please continue the work after checking the P
.C.B on a conveyor.
424202 Cnvr. Positioning2 P
.C.B. Detection
There is no P.C.B on the conveyer. After the P
.C.B. carrying in ended, it can not
able to be detected.
Please continue the work after checking the P.C.B on a conveyor.
424203 Cnvr. Positioning2 P
.C.B. Detection
No P.C.B. on the cnvr. After positioning released, P.C.B could not be detected.
Please continue the work after checking the P.C.B on a conveyor.
424204
Cnvr. Positioning2 P.C.B. Detection
The conveyer entrance sensor detected P.C.B.
Please continue the work after checking the P.C.B on a conveyor.
424205 Cnvr. Positioning2 P.C.B. Detection
The P
.C.B. that has not been positioned exists.
Please position the P.C.B.
424206 Cnvr. Positioning2 P.C.B. Detection
An unsuitable detected state of the sensor is being kept.
When you remove the factor which the sensor has detected and there is a
P.C.B in the way of carrying in, please return on input buffer cnvr. and resume
production by WarmStart.
424207
Cnvr. Positioning2 P.C.B. Detection
The P.C.B was unsuitable detected at the time of a carrying-in operation start.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
3-23
3.3 Conveyor
0707-001
Erroe ID Error Name, Description, Cause, and Remedy
424208 Cnvr. Positioning2 P.C.B. Detection
The P.C.B was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
424301 Cnvr. Positioning2 Error
The carrying in operation was not able to begin.
-----
424302 Cnvr. Positioning2 Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor.
424303 Cnvr. Positioning2 Error
The exhaust operation was not able to begin.
-----
424304 Cnvr
. Positioning2 Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
424305 Cnvr. Positioning2 Error
The error was detected while the backup base was rising.
-----
424306 Cnvr. Positioning2 Error
The error was detected while the backup base was descending.
-----
424307 Cnvr. Positioning2 Error
Rise operation of a PCB stopper is not completed.
Please check a stopper.
424308 Cnvr. Positioning2 Error
Downward operation of a PCB stopper is not completed.
Please check a stopper
.
424309 Cnvr. Positioning2 Error
The positioning change operation was not able to begin.
-----
424310 Cnvr. Positioning2 Error
The error was detected while the positioning change was operating.
Please continue the work after checking the P.C.B on a conveyor
.
424311 Cnvr. Positioning2 Error
The reversal positioning operation was not able to begin.
-----
424312 Cnvr. Positioning2 Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
424313 Cnvr
. Positioning2 Error
Pickup of a P.C.B went wrong.
Please check the existence of P.C.B or whether the support Jig has reached the
P.C.B.
3-24
3.3 Conveyor
0707-001
Erroe ID Error Name, Description, Cause, and Remedy
424314 Cnvr. Positioning2 Error
The pickup OFF of a P.C.B went wrong.
-----
424315 Cnvr. Positioning2 Error
Slowdown operation was not carried out at the time of carrying-in operation.
Please check whether the sensor of a conveyor is operating normally and check
whether a P.C.B can convey normally by manual conveyance.
424316 Cnvr. Positioning2 Error
Rise operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
424317 Cnvr. Positioning2 Error
Downward operation of a reversal PCB locate stopper is not completed.
Please check a stopper.
424318 Cnvr. Positioning2 Error
The P.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P
.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
424319
Cnvr. Positioning2 Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
4243
20 Cnvr. Positioning2 Error
The P.C.B. transfer operation could not start.
-----
4243
21 Cnvr. Positioning2 Error
An error was detected in transferring the P
.C.B..
Please continue the work after checking the P.C.B on a conveyor.
424322 Cnvr. Positioning2 Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B.
And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly
424323 Cnvr
. Positioning2 Error
A servo error was found in the movement that the backup base was rising. The
backup jig and pins may be left under the transfer rail.
Cancel the error and perform zeroing operation after that, open the cover to
remove the left backup jig and pins under the transfer rail. Perform the setup
operation again to set the backup jig and the pins to the proper positions.
424324 Cnvr
. Positioning2 Error
Support pins /Jig were detected before the backup base starts to rise.
Remove the support pins / jig from the backup base. If the removong operation is