4OM-1429-008_w.pdf - 第173页

3-12 0707-001 3.2 Data Erroe ID Error Name, Description, Cause, and Remedy 410306 Pattern Program Error The error is found in the nozzle candidate number of the conversion pattern program. ----- 410307 Pattern Program Er…

100%1 / 279
3-110707-001
3.2 Data
3.2 Data
Table 4C4
Erroe ID Error Name, Description, Cause, and Remedy
410101 Data Error
Machine data and system data error detected.
-----
410102 Data Error
Auto run start mode setup data error
-----
410103 Data Error
Steps in converted pattern program is more
-----
410104 Data Error
Pattern Program Errors(P
.E.C.Recog step error)
-----
410105 Data Error
The component library data used by the pattern program data doesn't exist.
-----
410106 Data Error
The nozzle type data registered in the nozzle data doesn't exist
-----
410107 Data Error
The nozzle type data registered in the nozzle data doesn't exist
-----
410201 Mode data Error
Abnormality is found in the production driving beginning mode setting data.
-----
410301 Pattern Program Error
Steps in converted pattern program is more
-----
410302 Pattern Program Error
There are Errors in converted pattern program(P
.E..C. recog steps Error.)
-----
410303 Pattern Program Error
The converted pattern program is not exist, the data is damaged.
-----
410304 Pattern Program Error
The error is found in the adsorption nozzle number of the conversion pattern
program.
-----
410305 Pattern Program Error
The error is found in the order of adsorption of the conversion system pattern
program.
-----
3-120707-001
3.2 Data
Erroe ID Error Name, Description, Cause, and Remedy
410306 Pattern Program Error
The error is found in the nozzle candidate number of the conversion pattern
program.
-----
410307 Pattern Program Error
The error is found in the adsorption lane number of the conversion pattern
program.
-----
410308 Pattern Program Error
The error is found in the alternation lane number of the comp arrangement data of
the conversion pattern program.
-----
410309 Pattern Program Error
The conversion of the pattern program did not end in prescribed time.
-----
410401 Component Library Data Error
The part library data used by the converted pattern program doesn't exist.
-----
410402 Component Library Data Error
The use nozzle candidate was not able to exchange nozzles because of the skip
specification.
-----
410501 Nozzle Data Error
The error is found in the head nozzle data of the device system data.
-----
410502 Nozzle Data Error
The error is found in the stocker nozzle data of the device system data.
-----
410601 Data Error
-----
410602 Data Error
Error is found in the
AUTO OPN MODE beginning mode setting data.
-----
410701 Program Error
It was a error setting of the sequence data was found.
-----
410702 Program Error
It was a error setting of the polling task was found.
-----
3-130707-001
3.3 Conveyor
3.3 Conveyor
Table 4C5
Erroe ID Error Name, Description, Cause, and Remedy
420701 P.C.B Stopper
It is set as "Use" of a positioning stopper in the system data, and the stopper
cannot be confirmed on a device.
Please confirm that a stopper works accurately.
420702 P.C.B Stopper
It is set as "Use" of a reversal positioning stopper in the system data, and the
stopper cannot be confirmed on a device.
Please confirm that a stopper works accurately.
420801 Manual transfer error
When operation started, error was detected.
-----
420802 Manual transfer error
Error was detected while operating.
-----
420803 Manual transfer error
Operation did not end in prescribed time.
-----
420804 Manual transfer error
It failed in reading P
.C.B information between stages .
-----
420901 Transfer Error (Others)
Please check the PCB on each conveyer.
-----
420902 Transfer Error (Others)
An error for timeout occurred in communication process during transfer process
startup.
Restart the operation.
420a01
Chute Clamp
It failed to release the chute clamp before NB-W axis operation. (Stage1)
Perform the operation again. If the failure occurs repeatedly, please confirm the
chute clamp pressure sensor.
420a02
Chute Clamp
It failed to release the chute clamp before NB-W axis operation. (Stage2)
Perform the operation again. If the failure occurs repeatedly, please confirm the
chute clamp pressure sensor.
420a03 Chute Clamp
It failed to release the chute clamp before NB-W axis operation.
Perform the operation again. If the failure occurs repeatedly, please confirm the
chute clamp pressure sensor
.
420a04 Chute Clamp
It failed to receive the information between stages at the chute clamp releasing
operation before NB-W axis operation.
Perform the operation again.