4OM-1429-008_w.pdf - 第167页
3-6 0712-002 3. Error IDs and Remedial Procedures Erroe ID Error Name, Description, Cause, and Remedy 400419 Interlock Error L2 axis(Front) Interlock Detected. Please confirm the nozzle has not fallen when you push the be…

3-50707-001
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
40040c Interlock Error
The feeder opening sensor (rear) was shaded. [B0512]
Please remove the factor which is shading the feeder opening sensor (rear), and
carry out zero return. (Continue with the warm start)
40040d Interlock Error
The feeder opening sensor (front) was shaded. [B0513]
Please remove the factor which is shading the feeder opening sensor (front), and
carry out zero return. (Continue with the warm start)
40040e Interlock Error
CB Alarm XY(Rear) Detected[Q201,Q221,Q222,Q223]
-----
40040f Interlock Error
CB Alarm XY(Front) Detected[Q201,Q221,Q222,Q223]
-----
400410 Interlock Error
CB Error (Conveyor/Cutter) Detected[Q203]
-----
400411 Interlock Error
CB Alarm(CPU2) Detected[Q214]
-----
400412 Interlock Error
CB Alarm(DC24) Detected[Q206]
-----
400413 Interlock Error
Lowered air pressure was detected. [K6]
-----
400414
Interlock Error
CB Alarm(Vacuum Pump)[Q205]
-----
400415 Interlock Error
The urgent stop reserve input was input.
Turn off the machine by pressing the emergency stop and after restarting it,
perform the zeroing operation.
400416 Interlock Error
NL axis(Front) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Please perform a zeroing.
400417 Interlock Error
NL axis(Rear) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Please perform a zeroing.
400418 Interlock Error
L1 axis(Front) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.

3-60712-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400419 Interlock Error
L2 axis(Front) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.
400420 Interlock Error
L3 axis(Front) Interlock Detected
Confirm of Path line/Head excess pushing detection.
400421 Interlock Error
L1 axis(Rear) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.
400422 Interlock Error
L2 axis(Rear) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.
400423 Interlock Error
L3 axis(Rear) Interlock Detected. Please confirm the nozzle has not fallen when
you push the beam by the hand.
Confirm of Path line/Head excess pushing detection.
400424 Interlock Error
The vacuum sensor's OFF of a P.C.B vacuum support Jig was detected during
P.C.B positioning.
Please confi
rm the P.C.B.
400425 Interlock Error
An emergency stop switch is pushed.
Please switch on a power supply after canceling an emergency stop switch and
screen return to normal display.
400426 Interlock Error
NL- L conveyor cover open was detected in the main machine.
Close the NL-L conveyor cover in the main machine and lock it.
40042
7 Interlock Error
NR- L conveyor cover open was detected in the main machine.
Close the NR-L conveyor cover in the main machine and lock it.
400428 Interlock Error
The safety cover lock was released.
Close the safety cover and lock it.
400429 Interlock Error
The secondary air pressure deterioration was detected.
Close the safety cover and lock it.
400430
Interlock Error
A pickup-failed component (Rear) were detected. [DA-B0510]
Open the safety cover and remove the failed component in the pickup operation
after that, execute the Warm start.

3-70712-002
3. Error IDs and Remedial Procedures
Erroe ID Error Name, Description, Cause, and Remedy
400431 Interlock Error
A pickup-failed component (Front) were detected. [DB-B0510]
Open the safety cover and remove the failed component in the pickup operation
after that, execute the Warm start.
400501 Lightning Surge Warning
Lightning Surge Protector works; L201,L202,L203. Please turn on the load power
supply after resetting error.
-----
400502 Lightning Surge Warning
-----
400503 Lightning Surge Warning
-----
400504 Lightning Surge Warning
-----
400505 Lightning Surge Warning
-----
400601 Servo Alarm
Servo Alarm Detected
-----
400602
Servo Alarm
All Beam alarm reseting API Error
-----
400701 Zero Return
Beam XY zeroing Error
-----
400702
Zero Return
When beam XY (Rear) starting zeroed, the standard mark gap was generated.
Please start up the power supply.
400703 Zero Return
When beam XY (Front) starting zeroed, the standard mark gap was generated.
Please start up the power supply.
400704 Zero Return
When beam XY (Rear) starting zeroed, recognition error of a standard mark was
generated.
-----
400705 Zero Return
When beam XY (Front) starting zeroed, recognition error of a standard mark was
generated.
-----