2-17 0712-002 3.2 List of Machine Information Machine Information Codes Display Field A (Scope of Machine Information) Display Field B (Details of Machine Information) 800D0D Maintenance Warning Keep the machine conditio…

2-160712-002
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
800901 Alarm For Shortage of Comp.
The tape end was detected.
800902 Alarm For Shortage of Comp.
Few components to feed.
800903 Alarm For Shortage of Comp.
A splicing tape was detected. (Alarm E3)
Resupply the component.
800A01 Product Information
Finished product interval :
800A02 Product Information
Auto run interval :
800A03 Product Information
Nozzle usage interval :
800A04 Product Information
Product started by RUN MODE "PASS"Operation.
800B01 Machine Interface Signal
No signal from furnace.
800C01 Cancel Recovery on
-----
800D01 Maintenance Warning
Trash box fill up warning.(notice count over)
800D02 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Oil-Checkup/Weekly)
800D03 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Oil-Checkup/1-Monthly)
800D04 Maintenance W
arning
Keep the machine condition.(maintenance cycle time : Oil-Checkup/3-Monthly)
800D05 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Oil-Checkup/6-Monthlyy)
800D06 Maintenance Warning
Keep
the ma
chine condition.(maint
enance cycle time : Oil-Checkup/Designate #1)
800D07 Maintenance Warning
Keep the machine condition.(maint
enance cycle time : Oil-Checkup/Designate #2)
800D08 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Upkeep-Checkup/Nozzle)
800D09 Maintenance Warning
Keep the machine condition.(maintenance cycle time : Upkeep-Checkup/Filter #1)
800D0A Maintenance Warning
Keep the machine condition.(maintenance cycle time : Upkeep-Checkup/Filter #2)
800D0B Maintenance Warning
Keep the machine condition.(maintenance cycle time : Designate-Checkup/Item
#1)
800D0C Maintenance Warning
Keep the machine condition.(maintenance cycle time : Designate-Checkup/Item
#2)

2-170712-002
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
800D0D Maintenance Warning
Keep the machine condition.(maintenance cycle time : Designate-Checkup/Item
#3)
800D0E Maintenance Warning
Component box fill up warning.(notice count over)
800D0F Maintenance Warning
It was the time of m
aintenance.
[A flux unit] Please perform cleaning of a flux spin
drum.
800E01 Program Change Warning
Check the setup of machine.(program change completed)
800E02 Program Change Warning
Check the setup of machine.(Program change completed. Run Mode changed to
"PASS".)
801001 Auto Offset Teach Information
Tape pocket recog error(run continue)
801101 Nozzle diameter confirmation
The disagreement of the nozzle diameter was detected with the linear measure.
There is a possibility of the linear measure dirt and the nozzle dirt,please confirm
whether a different nozzle has adhered.
801201 Stat Auto Head Recovery
Cpu Communication error occurred.(CPU2-CPU3)
801202 Stat Auto Head Recovery
Head cam origin return action not complete.(Not CAM ORIGIN position)
801203 Stat Auto Head Recovery
Head Driver communication is time out.(from cpu3 job)
801204
Stat Auto Head Recovery
Nozzle change action not complete.(cam lock action NG)
801205 Stat
Auto Head Recovery
Head cam position return action not complete.
801206 Stat Auto Head Recovery
Nozzle change action not complete.(cam free action NG)
801207 Stat Auto Head Recovery
Nozzle change action not complete.(Not CAM ORIGIN position)
801208 Stat Auto Head Recovery
Unselected Nozzle Drop.
801209 Stat Auto Head Recovery
Component output error(Pickup error) is detected by nozzle level was position.
;Nozzle posture detection
80120a Stat Auto Head Recovery
The selected nozzle was not at position. ;Nozzle posture detection
80120b Stat Auto Head Recovery
Component output error(Others) is detected by nozzle level was position. ;Nozzle
posture detection

2-180707-001
3.2 List of Machine Information
Machine
Information Codes
Display Field A (Scope of Machine Information)
Display Field B (Details of Machine Information)
801301 Pickup Position Feedback
Feedback value out of range. Please check feeder.
801401 Data Check
Pickup Level Data(Calculated data) is out of range. Please check library data and
offset data.
801402 Data Check
Placement height Data(Calculated data) is out of range. Please check library data
and offset data.
801403 Data Check
The data out of the setting range is contained in the feeder offset B data of
system data. On edit screen, X/Y of the components (tape width 8mm / sending
pitch 2mm) should be set as more than -1.0mm and less than +1.0mm.
801404 Data Check
The data out of the setting range is contained in the placement level data of
component supply changed data. On edit screen, the place level of square shape
below 3216 should be set up less than +0.5mm. When the place level exceeding
0.5mm is required, please input H data of placement data (PP data).
801501 Feeder Index Position
Production operation was interrupted in the middle of feeder index operation.
Please check a position.
801502 Feeder Index Position
The feeder carriage was returned to the home position in the middle of feeder
index operation. Please check a feeder index position.
801601 Product Restart
Restart production with semi-auto(after specified step) mode.
801602 Product Restart
Restart production with warm start mode.
801603 Product Restart
Restart production with warm start mode. Machine will stop after placement
complete. Please confirm PCB afterward.
801701 Teach Nozzle Bypass
Nozzle Down Error.(L)
801702 Teach Nozzle Bypass
Nozzle Down Error
.(H)
801703 T
each Nozzle Bypass
Recognition Teach Error.
80170
4 Teach Nozzle Bypass
Teach Error Data.
801705
Teach Nozzle Bypass
Lighting Check.
801706 T
each Nozzle Bypass
Nozzle Level.
801707 Teach Nozzle Bypass
Nozzle Drop