4OM-1429-008_w.pdf - 第92页

1-32 3.3.7 Head Section Coupling Linear Measure Sensors (Light Emitter and Receiver) Every Day Cleaning Required T ime: 5 minutes If sebum and oil, etc., adhere to the surface of the linear measure sensor , wipe them off…

100%1 / 279
1-31-1
When the tape guide is
detached or attached,
be sure to keep the Y-axis
linear scale free of nicks
and scratches.
Notice
Tape Guide
Attachment Position of
Cut Unit Fixing Jig
Fluorine Sheet, Urethane Clamp
Every Year Replacement Required Time: 5 minutes
(1) Remove four screws and detach the tape guide.
(2) Use the outer hole of the cut unit fixing jig and
attach the jig with the bent portion being directed
downward.
(3) Replace the fluorine sheet and the urethane clamp.
Refer to "4.3 Replacement of Fluorine Sheet
and Urethane Clamp" for the replacement
procedure.
Note
After the fluorine sheet has been replaced,
activate the cutter without a tape and cut the
fluorine sheet.
Reference
Fig. 4A19-4
3.3 Inspection, Cleaning, and Lubrication Spots
0712-001
1-32
3.3.7 Head Section
Coupling
Linear Measure Sensors
(Light Emitter and Receiver)
Every Day Cleaning
Required Time: 5 minutes
If sebum and oil, etc., adhere to the surface
of the linear measure sensor, wipe them
off with a cotton swab soaked in absolute
ethanol.
(2 places)
Every Month Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
(1) Wipe off the old grease with a rag and
apply a small amount of new grease
with a syringe.
(2) Move the NL-axis 19 mm up and down
using the manual (inching) operation
to create a smooth coating grease.
(3) Wipe off excess grease.
Take ample care not to leave
any waste threads after
cleaning.
Use No. 18 (green) nozzle.
No.18
Notice
Note
Notice
Diffusion Plate
Every Month Cleaning
Required Time: 2 minutes
(1) Store all nozzles in the nozzle stocker
(housing) through window navigations.
(2) Wipe the diffusion plate with a dry
lens cleaning cloth.
Sebum or oil should not
adhere to the surface of the
diffusion plate.
Refer to "6. "Nozzle Change"
Window" in "Chapter 3 (Vol. 2)"
for the procedure of nozzle storage.
Nozzle U/D Ball Screw (NL Axis)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 5 minutes
Wipe off the old grease with a rag and
apply a small amount of new grease to the
groove of the ball screw with a syringe.
Use No. 19 (brown) nozzle.
Note
No. 19
Reference
Nozzle U/D Linear Guides (NL Axis)
Fig. 4A20
3.3 Inspection, Cleaning, and Lubrication Spots
0811-003
1-33
3.3 Inspection, Cleaning, and Lubrication Spots
Nozzle Change Cam Face (Lower Side)
Every 3 Months Cleaning and Lubrication
(DAPHNE EPONEX GREASE No. 1)
Required Time: 2 minutes
If a foreign substance adheres to the
nozzle change cam face, remove them with
a pair of tweezers.
Apply grease (0.01 cc) to the cam face with
a syringe.
(a) "0.01 cc" is almost equivalent
to the size of "1005 Chip".
(b)
Use No. 19 (brown) nozzle.
Note
No. 19
Fig. 4A21
0811-002