4OM-1429-008_w.pdf - 第177页

3-16 3.3 Conveyor Erroe ID Error Name, Description, Cause, and Remedy 421303 Input Buffer Cnvr . Error The exhaust operation was not able to begin. ----- 421304 Input Buffer Cnvr . Error The error was detected while exha…

100%1 / 279
3-150707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421208 Input Buffer Cnvr. P.C.B. Detection
Manual bypass of the P.C.B was carried out in the state where a P.C.B is on a
conveyor.
Please remove the P.C.B carried out by manual bypass. Production can be
continued.
421209 Input Buffer Cnvr. P.C.B. Detection
The P.C.B was not found in the proper position.
Please remove the P.C.B on a conveyor. Production can be continued.
421210 Input Buffer Cnvr. P
.C.B. Detection
Manual bypass of the P.C.B which is not a P.C.B transfer position can not be
done.
Please close the cover. Production can be continued.
421211 Input Buffer Cnvr. P
.C.B. Detection
The P.C.B on a conveyor was removed.
Please close the cover. Production can be continued.
421212 Input Buffer Cnvr. P
.C.B. Detection
The P.C.B was detected with the conveyer entrance sensor.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
421213
Input Buffer Cnvr. P.C.B. Detection
A P.C.B. was detected with the conveyor entrance sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor
, continue the product operation. If no
P.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
421214 Input Buffer Cnvr. P.C.B. Detection
A P.C.B. was detected with the conveyor exit sensor upon completion of the
output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P
.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
421215 Input Buffer Cnvr. P.C.B. Detection
A P.C.B. was detected with the both sensors of the conveyor entrance and exit
upon completion of the output operation.
After checking the P.C.B. on the conveyor, continue the product operation. If no
P
.C.B. is there, remove the factor why the sensor was detected upon completion
of the output operation.
421301 Input Buffer Cnvr. Error
The carrying in operation was not able to begin.
-----
421302 Input Buffer Cnvr. Error
The error was detected while carrying in was operating.
Please continue the work after checking the P.C.B on a conveyor.
3-16
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421303 Input Buffer Cnvr. Error
The exhaust operation was not able to begin.
-----
421304 Input Buffer Cnvr. Error
The error was detected while exhaust was operating.
Please continue the work after checking the P.C.B on a conveyor.
421305 Input Buffer Cnvr. Error
The P.C.B. transport to receiving position was not able to begin.
-----
421306 Input Buffer Cnvr. Error
The error was detected while transporting to the receiving position.
-----
421307 Input Buffer Cnvr. Error
The operation moving to the arrangement position was not able to begin.
-----
421308
Input Buffer Cnvr. Error
The error was detected while transporting to the arrangement position.
-----
421309
Input Buffer Cnvr. Error
The input machine work transfer signal was turned off before the completion of
PCB carrying-in operation.
Please continue the work after checking the P.C.B on a conveyor
.
421310 Input Buffer Cnvr. Error
The reversal positioning operation was not able to begin.
-----
42131
1 Input Buffer Cnvr
. Error
The error was detected while the reversal positioning was operating.
Please continue the work after checking the P.C.B on a conveyor.
42131
2 Input Buffer Cnvr
. Error
Conveyor width The conveyor upper cover by input side opened during axial
operation.
Please close a cover and perform again.
421313 Input Buffer Cnvr. Error
The conveyor upper cover by input side opened during production operation and
equipment operation.
Please close a cover and perform again.
421314 Input Buf
fer Cnvr. Error
The Input conveyor upper cover opened during production operation and
equipment operation.
Please close a cover and perform again.
421315 Input Buf
fer Cnvr. Error
It changed into the conveyor operation forbidden state during axial operation of
conveyor width. (The conveyor operation forbidden signal from Input conveyor
was detected.)
Please cancel the forbidden operation state of a conveyor and perform again.
0707-001
3-170707-001
3.3 Conveyor
Erroe ID Error Name, Description, Cause, and Remedy
421316 Input Buffer Cnvr. Error
The P.C.B was transported a predetermined distance, but the operation was not
completed.
There is a possibility that the P.C.B fell over from conveyer whether a board is
caught. Please confirm it over a conveyer.
421317 Input Buffer Cnvr. Error
Bar code information cannot be acquired definitely.
Please take out the P.C.B from a conveyer, and acquire bar code information
again.
421318 Input Buffer Cnvr
. Error
It detec
ted a Bo
ardAvailable signal in the state that a device cannot take in a P.C.B
from input.
Please get rid of the factor so that a BoardAvailable signal does not appear.
421319 Input Buffer Cnvr. Error
The process of inside signal between conveyors failed.
Please continue the work after checking the P.C.B on a conveyor.
421320 Input Buffer Cnvr. Error
Speed reduction was not performed during transferring operation.
Please return the P.C.B. to the proper position when it is sitting between the
conveyors otherwise, remove the P.C.B. And, the P.C.B. detection sensor might
have had a wrong detection, so please check it to make detections correctly.
421321 Input Buffer Cnvr. Error
An error occurred during END P.C.B. transfer operation.
Put the P
.C.B. on the input conveyor and perform the "START". The product
operation can be continued that why the machine considers as if the P.C.B. put
was the end P.C.B..
422101 Cnvr
. Positioning1 Overtime
P.C.B. from inp. buffer cnvr. was not received.
Please continue the work after checking the P.C.B on a conveyor.
422102 Cnvr. Positioning1 Overtime
P
.C.B. moving to inp. buffer cnvr. was not received
Please continue the work after checking the P.C.B on a conveyor.
422103 Cnvr. Positioning1 Overtime
The rising operation of the backup base did not end in prescribed time.
-----
422104 Cnvr. Positioning1 Overtime
The descent operation of the backup base did not end in prescribed time.
-----
422105
Cnvr. Positioning1 Overtime
The P.C.B. transport (exhaust) to output cnvr. did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.
422106 Cnvr
. Positioning1 Overtime
The positioning change operation did not end in prescribed time.
Please continue the work after checking the P.C.B on a conveyor.