4OM-1429-008_w.pdf - 第200页

3-39 3.7 Automatic Setup 0707-001 Erroe ID Error Name, Description, Cause, and Remedy 490707 Nozzle set up There is no free space for nozzle storing. Please confirm the arrangement data. Please confirm the Stocker arrangem…

100%1 / 279
3-380707-001
3.7 Automatic Setup
Erroe ID Error Name, Description, Cause, and Remedy
49061c Conveyor Width Automatic Adjustment
Head Up/Down Axis Zeroing Error.
-----
49061d Conveyor Width Automatic Adjustment
The P.C.B was detected on the Input conveyor.
Please remove the P.C.B on a Input conveyor.
49061e Conveyor Width Automatic Adjustment
The P.C.B was detected on the Cnvr. Positioning1.
Please remove the P.C.B on a Cnvr
. Positioning1.
49061f Conveyor Width Automatic Adjustment
The P.C.B was detected on the central conveyor
.
Please remove the P.C.B on a central conveyor.
490620 Conveyor Width Automatic Adjustment
The P.C.B was detected on the Cnvr
. Positioning2.
Please remove the P.C.B on a Cnvr. Positioning2.
490621 Conveyor Width Automatic Adjustment
The P.C.B was detected on the Output conveyor
.
Please remove the P.C.B on a Output conveyor.
490690 Conveyor Width Automatic Adjustment
Auto Setup Error(Others).
-----
490701 Nozzle set up
Nozzle Stocker is not set.
Please check whether it is correctly set to the stocker base.
490702
Nozzle set up
Motor Error Detection.
-----
490703 Nozzle set up
Nozzle Stocker Shutter open/close failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490704 Nozzle set up
Nozzle Stocker up/dowon failed.
There is no float going up of a nozzle, or please check whether there is any
connection etc. in opening and closing.
490705 Nozzle set up
An error occurred with the nozzle existence check in the stocker before the nozzle
is placed.
Please check whether there is any dif
ference in stocker arrangement data and
real arrangement.
490706
Nozzle set up
Head nozzle existence confirmation has error.
Please check whether there is any difference in head arrangement data and real
arrangement.
3-39
3.7 Automatic Setup
0707-001
Erroe ID Error Name, Description, Cause, and Remedy
490707 Nozzle set up
There is no free space for nozzle storing. Please confirm the arrangement data.
Please confirm the Stocker arrangement data.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
Please set up an insufficient nozzle in Noz stocker.
490709 Nozzle set up
Nozzle exchange abnormal data was found.
Please confirm the nozzle arrangement and the Stocker arrangement data.
49070a Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Noz stocker position again on the instruction screen.
49070b Nozzle set up
Placement Hd / Noz data is not corresponding to the real arrangement.
Please confirm the real arrangement of the head nozzle arrangement data and
the head.
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
and confirm there is no unexpected value.
49070d Nozzle set up
It failed in the nozzle placement check. Confirm the recognition image and select
the nozzle existence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this
position.
Please confi
rm the nozzle has not adhered to the position. Moreover, please
clean the linear measure when not adhering.
49070f
Nozzle set up
The placed nozzle was undetectable on the head otherwise, the nozzle was not
placed correctly or dust was detected.
Please confirm whether the nozzle has adhered to the position.
490710 Nozzle set up
The receipt nozzle was undetectable on the head.
Please confi
rm whether the nozzle has adhered to the position.
490711 Nozzle set up
The remains nozzle was detected on the head.
Please confi
rm the nozzle has not adhered to the position. Moreover, please
clean the linear measure when not adhering.
490712 Nozzle set up
The linear measure error occurred in the head nozzle existence check.
Please confirm the nozzle arrangement, and execute the level teaching.
3-400707-001
3.7 Automatic Setup
Erroe ID Error Name, Description, Cause, and Remedy
490713 Nozzle set up
The nozzle exchange sequence error occurred.
Please confirm the nozzle placement.
490714 Nozzle set up
The nozzle placement in Nozzle stocker is different from the nozzle data.
Please confirm the nozzle placement.
490715 Nozzle set up
It failed in nozzle ID detection.
Please confirm the nozzle ID.
490716 Nozzle set up
Time-out of close nozzle stocker operation.
Nozzle stocker was opened for safety. Please confirm whether there is no rise to
the surface the nozzle is not in opening and shutting caught state.
490717 Nozzle set up
-----
490718 Nozzle set up
-----
490719 Nozzle set up
-----
490720 Nozzle set up
-----
490721 Nozzle set up
-----
490722 Nozzle set up
An
error occurred with the nozzle existence
check in the stocker before the nozzle
is stored.
-----
490723 Nozzle set up
It failed in the nozzle storage check. Confirm the recognition image and select the
nozzle existence.
-----
490801
Program -change linked operation
Program-change linked operation was not finished within appointed time.
-----