3-40 0707-001 3.7 Automatic Setup Erroe ID Error Name, Description, Cause, and Remedy 490713 Nozzle set up The nozzle exchange sequence error occurred. Please confirm the nozzle placement. 490714 Nozzle set up The nozzle …

3-39
3.7 Automatic Setup
0707-001
Erroe ID Error Name, Description, Cause, and Remedy
490707 Nozzle set up
There is no free space for nozzle storing. Please confirm the arrangement data.
Please confirm the Stocker arrangement data.
490708 Nozzle set up
There are neither a free space nor a nozzle for nozzle exchange.
Please set up an insufficient nozzle in Noz stocker.
490709 Nozzle set up
Nozzle exchange abnormal data was found.
Please confirm the nozzle arrangement and the Stocker arrangement data.
49070a Nozzle set up
Nozzle stocker position teaching failed.
Please teach the Noz stocker position again on the instruction screen.
49070b Nozzle set up
Placement Hd / Noz data is not corresponding to the real arrangement.
Please confirm the real arrangement of the head nozzle arrangement data and
the head.
49070c Nozzle set up
Nozzle level teach error Detection.
Please execute the nozzle level teaching again on the nozzle level teach screen,
and confirm there is no unexpected value.
49070d Nozzle set up
It failed in the nozzle placement check. Confirm the recognition image and select
the nozzle existence.
Please select a recognition image and choose the existence of a nozzle.
49070e Nozzle set up
The remains nozzle was detected on the head. The nozzle cannot be set to this
position.
Please confi
rm the nozzle has not adhered to the position. Moreover, please
clean the linear measure when not adhering.
49070f
Nozzle set up
The placed nozzle was undetectable on the head otherwise, the nozzle was not
placed correctly or dust was detected.
Please confirm whether the nozzle has adhered to the position.
490710 Nozzle set up
The receipt nozzle was undetectable on the head.
Please confi
rm whether the nozzle has adhered to the position.
490711 Nozzle set up
The remains nozzle was detected on the head.
Please confi
rm the nozzle has not adhered to the position. Moreover, please
clean the linear measure when not adhering.
490712 Nozzle set up
The linear measure error occurred in the head nozzle existence check.
Please confirm the nozzle arrangement, and execute the level teaching.

3-400707-001
3.7 Automatic Setup
Erroe ID Error Name, Description, Cause, and Remedy
490713 Nozzle set up
The nozzle exchange sequence error occurred.
Please confirm the nozzle placement.
490714 Nozzle set up
The nozzle placement in Nozzle stocker is different from the nozzle data.
Please confirm the nozzle placement.
490715 Nozzle set up
It failed in nozzle ID detection.
Please confirm the nozzle ID.
490716 Nozzle set up
Time-out of close nozzle stocker operation.
Nozzle stocker was opened for safety. Please confirm whether there is no rise to
the surface the nozzle is not in opening and shutting caught state.
490717 Nozzle set up
-----
490718 Nozzle set up
-----
490719 Nozzle set up
-----
490720 Nozzle set up
-----
490721 Nozzle set up
-----
490722 Nozzle set up
An
error occurred with the nozzle existence
check in the stocker before the nozzle
is stored.
-----
490723 Nozzle set up
It failed in the nozzle storage check. Confirm the recognition image and select the
nozzle existence.
-----
490801
Program -change linked operation
Program-change linked operation was not finished within appointed time.
-----

3-41
3.7 Automatic Setup
0712-002
Erroe ID Error Name, Description, Cause, and Remedy
496101 Conveyor Width Automatic Setup
The initialization is imperfect.
(1) Power on the machine again. (2) The transfer driver has a problem.
496102 Conveyor Width Automatic Setup
It failed in zeroing operation.
Perform zeroing operation.
496103 Conveyor Width Automatic Setup
An alarm for the interference is occurring.
-----
496104 Conveyor Width Automatic Setup
DI was detected.
-----
496105 Conveyor Width Automatic Setup
The conveyor cover opened.
Close the conveyor cover.
496106 Conveyor Width
Automatic Setup
Voltage reduction on the power source was detected.
Check the transfer driver.
496107 Conveyor Width
Automatic Setup
OT (+) was detected during auto operation.
Perform zeroing operation.
496108 Conveyor Width
Automatic Setup
OT (-) was detected during auto operation.
Perform zeroing operation.
496201 Conveyor Width
Automatic Setup (Input conveyor W2)
The initialization is imperfect.
(1) Power on the machine again. (2) The transfer driver has a problem.
496202 Conveyor Width Automatic Setup (Input conveyor W2)
It failed in zeroing operation.
Perform zeroing operation.
496203
Conveyor Width Automatic Setup (Input conveyor W2)
An alarm for the interference is occurring.
-----
496204 Conveyor Width
Automatic Setup (Input conveyor W2)
DI was detected.
-----
496205 Conveyor Width Automatic Setup (Input conveyor W2)
The conveyor cover opened.
Close the conveyor cover.
496206
Conveyor Width Automatic Setup (Input conveyor W2)
Voltage reduction on the power source was detected.
Check the transfer driver
.
496207 Conveyor Width Automatic Setup (Input conveyor W2)
OT
(+) was detected during auto operation.
Perform zeroing operation.