KE-750_MAINTE.pdf - 第106页
- 103 - 11 SCM Error A hardware error whose cause cannot be specified but related to the CPU board of the SCM. Ditto 13 Bad EEPROM Data SCM EEPROM reports a data error. If t he error occurs again when the power is turned…

- 102 -
68
Big Part
The shade of the part exceeded one
end or both ends of the window.
When Error Level is set 2, this error
will not occur in most cases, and the
codes 76 to 82 appear.
Check whether the dimensions of the
part exceeds the specified value.
76
Width Error for
Algorithm 11
With algorithm 14, an appropriate
slant in the change of width to the
angle could not be obtained. The
part is not completely block the laser
stripe, or algorithm to be set 14 is set
11.
Check that the laser height and the part
data of the part is correct.
77
Width Error for
Algorithm 14
With algorithm 14, an appropriate
slant in the change of width to the
angle could not be obtained. The
part is not completely block the laser
stripe, or algorithm to be set 14 is set
11.
Check that the laser height of the part is
correct.
79
Window Blocked
Entire window has been blocked.
The part is too large, or the amount of
laser beam has decreased.
The operator is instructed to check
whether the part size is within the
specified value. If this occurs many
times even when the part size is within
the specified value, the amount of the
laser beam decreases. Therefore,
check the output level of the sensor (the
Milky Way). If it is not within the
specified level, the sensor head has to be
replaced.
99
Overrun
Before the detection of the next
minimum value specified for hold off
angle starts, the necessary process
has not been completed. The
detailed error of code 65 (Error Level
2). The part is not correctly picked,
and there are too many changes in
the shade of the part. Or, the hold
off angle of 2nd and after is too small,
and start angle is set within the
previous data collection area.
Check whether the dimensions of the
part exceeds the specified value.
Reset/power on again error
Error code Cause of error Action
03, 04
No FIFO Data,
No RAM Data
The sensor is not connected, or the
hardware is faulty.
The operator is asked, to turn off the
power, to check the connection of the
cables, and then to turn on the power
again. If the same error occurs after
recovery of the possible cause, the
hardware is faulty and it shall be
replaced.
08
No Start
Ditto Ditto
10
Sensor Error
A hardware error whose cause cannot
be specified but related to the sensor
and the coaxial link.
Ditto

- 103 -
11
SCM Error
A hardware error whose cause cannot
be specified but related to the CPU
board of the SCM.
Ditto
13
Bad EEPROM
Data
SCM EEPROM reports a data error. If the error occurs again when the power
is turned off and on, it shall be replaced.
14
Bad EEPROM
Sync
Ditto Ditto
83
Bad Checksum
A software error has been detected
when reading the data in EEPROM.
Ditto
84
Duplicate Start
Ditto Ditto
85
No EEPROM Start
of Data
Ditto Ditto
Hardware replacement error
Error code Cause of error Action
02
Laser Fail
The laser diode is faulty. The sensor has to be replaced.
09
FIFO Error
The hardware of the SCM is faulty. The SCM board has to be replaced.
12
Bad EEPROM
Version
The software does not recognize the
EEPROM version of the SCM.
The ROM of the SCM board has to be
replaced.
103
Low Background
The amount of laser beam is too small
for image check.
The sensor has to be replaced.
104
Bad Image Check
Region
The boundary of the image check
range has not been correctly set.
The sensor has to be replaced.
105
Image Check Fail
Image check failed the parameter
comparison.
The sensor has to be replaced.
Software fault error
Error code Cause of error Action
70
Algorithm Error
Impossible status of firmware has
been detected.
Consult JUKI (Developer).
90
Too Few Frames
The software is faulty. Consult
CyberOptics.
Ditto
91
Minimum Out of
Range 1
Ditto Ditto
92
Minimum Out of
Range 2
Ditto Ditto

- 104 -
94
No Cutoff 1
Ditto Ditto
95
No Cutoff 2
Ditto Ditto
96
Constant Angle
Ditto Ditto
101
Page Mismatch
Spare. Consult CyberOptics. Ditto
Other errors
Error code Cause of error Action
07
No Algorithm
NO_ALG has been requested. Consult JUKI (Developer).
69
DPRAM
An error of Dual Port RAM. This is
impossible to happen because that
RAM is not used.
Ditto
72
More Pages
A
n error related to Window command.
This can occur when Window 1 has
been specified with SCM2. This is
impossible to happen because only
Window 0 is used.
Ditto
73
More Counters
This error can occur when encoder
No.1 has been specified with SCM2.
This is impossible to happen because
only encoder No.0 is available.
Ditto
74
More Windows
This error can occur when Window
No.1 has been specified with SCM2.
This is impossible to happen because
only Window No.0 is available.
Ditto
75
Previous Error
An error has occurred with the
previous algorithm.
Ditto
78
Small Window
The window size has been for set less
than 8 pixels.
Ditto
86
Bad Parameter
An invalid parameter has been set. Ditto
87
Bad Data
Invalid data has been detected. It is
necessary to check whether a valid
data has been included in the
program sequence or a command
error has occurred.
Ditto
93
Minimum Too High
The change in the curve to the angle
is too small. This is likely to occur
when a small part is turned at low
speed.
Ditto
100
Units Not Set
Required initialization has not been
performed yet.
Ditto
102
Invalid Algorithm
A invalid algorithm has been sent. Ditto