KE-750_MAINTE.pdf - 第177页

- 36 - No. Item A bbreviation Meaning Meaning of N, X, and Y 9 Others 2 pGx3Ctrl->wDiffCompoRatio pGx3Ctrl->wDiffCompoChip pGx3Ctrl->wDiffCompoOther pGx3Ctrl->stNzlChgRange. lX pGx3Ctrl->stNzlChgRange. lY …

100%1 / 228
- 35 -
(3) Others
No. Item Abbreviation Meaning
Meaning of
N, X, and Y
1 Nozzle information
pGx3Ctrl->stNozzle [X]. byNozzleThreshold
pGx3Ctrl->stNozzle [X]. byCmpntThreshold
pGx3Ctrl->stNozzle [X]. byTimeout
pGx3Ctrl->stNozzle [X]. byPlaceVacuumWait
pGx3Ctrl->stNozzle [X]. byCmpntThreshold2
pGx3Ctrl->stNozzle [X]. stPick. lX
pGx3Ctrl->stNozzle [X]. stPick. lY
Nozzle YES/NO check threshold
Part YES/NO check threshold (check when
picked)
Waiting time for part YES/NO check completion
Waiting time for mount vacuum off
Part YES/NO check threshold (Check before
mounting)
X direction simultaneous pick range
Y direction simultaneous pick range
X is nozzle
number.
(*NOTE 14)
2 ATC
pGx3Ctrl->stXy. stAtc [X]. wZDownWait
pGx3Ctrl->stXy. stAtc [X]. wZUpWait
pGx3Ctrl->stXy. stAtc [X]. wTimeout
pGx3Ctrl->stXy. stAtc [X]. wCloseTime
Waiting time for Z down
Time from plate sensor on to Z up
Timeout duration from plate open/close to plate
sensor check
Time for plate close operation completion
X = 0 (used)
X = 1 (Spare)
3 Laser read locator
pGx3trl->stL3. lAccelSection
pGx3trl->stL3. lScanFromTip
pGx3trl->stL3. lRetryPitch
pGx3trl->stL3. lRetry
Acceleration distance for detection
Scanning position from the pin tip
Offset amount of scanning position for retry
The number of retries
4 Others
pGx3Ctrl->wPushInPlace
pGx3Ctrl->wPushInPick
pGx3Ctrl->wPreLoadStarTime [X]
pGx3Ctrl->wPickAdjustTime
pGx3Ctrl->wChipCoef
Push in amount when mounting
Push in amount when picking
Pre-load start time
The number of automatic pick position correction
Coefficient for part rise detection height
computation
X: (*NOTE
15)
5 Version information
pGx3Ctrl->symbol
pGx3Ctrl->stKind. byspec
pGx3Ctrl->stKind. byStructVer
pGx3Ctrl->stKind. byPrmtrVer
Symbol (Information on initialization)
Mechanism parameters per specification
Version of body
Version of data content (Default values)
6 Vacuum waiting time (ms) per part type
pGx3Ctrl->stCmpnt [X]. wPickVac
pGx3Ctrl->stCmpnt [X]. wPlaceVac
pGx3Ctrl->stCmpnt [X]. wBlowOff
pGx3Ctrl->stCmpnt [X]. wVacOff
pC [X]. wPickVac
pC [X]. wPlaceVac
pC [X]. wBlow
pC [X]. wVacOff
Waiting time for pick vacuum
Waiting time for mount vacuum
Blow stop duration before moving up of mount
Vacuum stop duration before completing to
move down mount Z axis
X is part
type. (*NOTE
16)
7 Vacuum waiting time 2 (ms) per part type
pGx3Ctrl->stCmpnt2 [X]. wBlowOn
pGx3Ctrl->stCmpnt2 [X]. wRsv1
pGx3Ctrl->stCmpnt2 [X]. wRsv2
pGx3Ctrl->stCmpnt2 [X]. wRsv3
pC [X]. wBlowOn
pC [X]. wRsv1
pC [X]. wRsv2
pC [X]. wRsv3
Blow start time before completing to move down
mount Z axis
Reserved
Reserved
Reserved
X is part
type. (*NOTE
16)
8 Other waiting times (ms)
pGx3Ctrl->stWaitTime. wVcsStd
pGx3Ctrl->stWaitTime. wVcs03
pGx3Ctrl->stWaitTime. wBocMark
pGx3Ctrl->stWaitTime. wIcMark
pGx3Ctrl->stWaitTime. wLaSweep
pGx3Ctrl->stWaitTime. wLaOnce
pGx3Ctrl->stWaitTime. wZPlace
pGx3Ctrl->stWaitTime. wScrapBlow
pGx3Ctrl->stWaitTime. wZGainLow
pGx3Ctrl->stWaitTime. wBadMark
Gx3Ctrl->stWaitTime. wRsv [Y]
pWT. wVcsStd
pWT. wVcs03
pWT. wBocMark
pWT. wIcMark
pWT. wLaSweep
pWT. wLaOnce
pWT. wZPlace
pWT. wScrapBlow
pWT. wZGainLow
pWT. wBadMark
pWT. wRsv [Y]
Time after moving Z axis to standard VCS until
taking the part image
Time after moving Z axis to 0.3 mm VCS until
taking the part image
Time after moving to the BOC mark until taking
the mark image
Time after moving to the IC mark until taking the
mark image
Time after starting to move XY axes until starting
SWEEP
Time after starting to move XY axes until starting
ONCE
Time after finishing to move XY axes until
moving down Z axis
Blow time when discarding parts
Low gain duration of Z axis
Time after moving to bad mark until taking the
mark image
Reserved
Y is the
number of
reservation.
- 36 -
No. Item Abbreviation Meaning
Meaning of
N, X, and Y
9 Others 2
pGx3Ctrl->wDiffCompoRatio
pGx3Ctrl->wDiffCompoChip
pGx3Ctrl->wDiffCompoOther
pGx3Ctrl->stNzlChgRange. lX
pGx3Ctrl->stNzlChgRange. lY
pGx3Ctrl->stVcsStdDist. lX
pGx3Ctrl->stVcsStdDist. lY
pGx3Ctrl->stVcsOptDist. lY
pGx3Ctrl->stVcsOptDist. lY
Coefficient for different part check (For the ratio
between depth and width)
Coefficient for different part check (Chip, Melf,
and SOT)
Coefficient for different part check (Those other
than above part types)
Range of X direction simultaneous nozzle
replacement
Range of Y direction simultaneous nozzle
replacement
Field to field distance when X direction split
recognition (For standard VCS)
Field to field distance when Y direction split
recognition (For standard VCS)
Field to field distance when X direction split
recognition (For optional VCS)
Field to field distance when Y direction split
recognition (For optional VCS)
10 Limit value of laser stain check
pGx3Ctrl->stLasChkLimit [X]. lDarkLevel
pGx3Ctrl->stLasChkLimit [X]. lMinPixel
pGx3Ctrl->stLasChkLimit [X]. lMinLowPass
pGx3Ctrl->stLasChkLimit [X]. lBackground
pGx3Ctrl->stLasChkLimit [X]. lMaxLowPass
pGx3Ctrl->stLasChkLimit [X]. lMaxPixel
pGx3Ctrl->stLasChkLimit [X]. lRmsMidFreq
pGx3Ctrl->stLasChkLimit [X]. lMaxMidFreq
pGx3Ctrl->stLasChkLimit [X]. lRmsHiFreq
pGx3Ctrl->stLasChkLimit [X]. lAbsHiFreq
pGx3Ctrl->stLasChkLimit [X]. lEvenOdd
pGx3Ctrl->stLasChkLimit [X]. lNonFlat
pLCL [X]. lDarkLevel
pLCL [X]. lMinPixel
pLCL [X]. lMinLowPass
pLCL [X]. lBackground
pLCL [X]. lMaxLowPass
pLCL [X]. lMaxPixel
pLCL [X]. lRmsMidFreq
pLCL [X]. lMaxMidFreq
pLCL [X]. lRmsHiFreq
pLCL [X]. lAbsHiFreq
pLCL [X]. lEvenOdd
pLCL [X]. lNonFlat
Dark Level
Min raw pixel value
Min low-pass filtered value
Median background level
Max low-pass filtered value
Max raw pixel value
RMS median filtered noise
Max median filtered error
RMS high frequency noise
Absolute high frequency noise
Even-odd pixel value mismatch
RMS low frequency noise
X: (*NOTE
17)
- 37 -
7. MEANING OF ARRANGEMENT
(TABLE 3: *DETAILED EXPLANATION OF NOTES)
(1) Head
No. Description
1 Head (Z axis)
*NOTE 1: X = 0
X = 1
X = 2
X = 3
X = 4
X = 5
X = 6
X = 7
X = 8
X = 9
X = 10
X = 11
X = 12
Moves up without parts.
Moves down without parts.
Moves up to laser height after part pick.
Moves up after part pick. (Other than laser height)
Moves down for part pick.
When moving up after part mount
When moving down for part mount
When moving up at recognition position
When moving down at recognition position
When moving up at ATC position
When moving down at ATC position
When moving up at other positions
When moving down at other positions
*NOTE 2: Y = 0
Y = 1
Y = 2
Y = 3
Y = 4
Y = 5
Y = 6
Y = 7
Y = 8
Y = 9
TYPE 0 (For details of TYPE 0 to TYPE 9, see Table 4.)
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
Head (Z axis) other than PTP operation
*NOTE 3: X = 0
X = 1
X = 2
X = 3
X = 4
X = 5
X = 6
X = 7 – 10
JOG start operation
JOG stop operation
STEP operation
PTP operation in upward direction for HOME
PTP stop operation in upward direction for HOME
PTP operation in downward direction for HOME
Step operation for HOME
Reserved
2 Head (θ axis)
*NOTE 4: X = 0
X = 1
X = 2
When pre-load
When measured
When rotating to part mount angle
*NOTE 5: Y = 0
Y = 1
Y = 2
Y = 3
Y = 4
Y = 5
Y = 6
Y = 7
Y = 8
Y = 9
TYPE 0 (For details of TYPE 0 to TYPE 9, see Table 4.)
TYPE 1
TYPE 2
TYPE 3
TYPE 4
TYPE 5
TYPE 6
TYPE 7
TYPE 8
TYPE 9
Head (θ axis) other than PTP operation
*NOTE 6: X = 0
X = 1
X = 2
X = 3
X = 4 – 6
JOG start operation
JOG stop operation
STEP operation
PTP operation of θ axis for HOME of 2nd time and after
Reserved
3 Head (Laser) hold off count
*NOTE 7: X = 0 – 9 Not used
Head (Laser) computation waiting time
*NOTE 7: X = 0 – 9 Not used
Head (Laser) pre-load angle
*NOTE 7: X = 0 – 5 Not used