3.8.2.3 Vacuum and blow timing of KE-750/760
Figure 7 shows the operation timing of each SV of vacuum and blow on
KE-750/760, and the changes in the pressure values at the tip of the nozzle at
that timing.
Vacuum
Blow
Negative pressure
Vacuum level
Atmosphere
Z axis
Figure 7
NOTE:
For Z axis: q is for square chip parts; w is for Melf, aluminum electrolytic
capacitor, network resistor, trimmer, SOT, SOJ, SOP, and PLCC; e is for QFP,
TSOP, BGA, connector, and socket.
- 95 -
- 96 -
As shown in Figure 7, the timing of vacuum off and that of blow on/off are the
same regardless of the part types. However, the parameter values of the
vacuum timer in Figure 6 differ for the part type because, for the Z axis, the
speed to move down and the time to be held differ per part type.
By performing blow control, the vacuum destruction time is shortened from 5 ms
(for KE-730/740 as shown in Figure 1) to 12 ms. As a result, a high vacuum
pressure can be maintained for mounting chip parts immediately before their
mount. For other part types, a high vacuum pressure is maintained until the
nozzle stops at the low position. Then, after releasing the vacuum pressure,
the nozzle is moved upward.
3.9 LA Operation
Measurement procedure for Laser Align Ver. 2.1
Setting window parameters
- 97 -
Holdoff angle: The angle until
the scanning starts to detect the
next minimum width.
Algorithm: The algorithm
used to compute the minimum
width from the result of scanning.
Holdoff Angle
85°
Algorithm
14
14
7
7
Angle Limit
60
120
∞
∞
*1
*1
Result 0
Result 1
Result 2
Result 3
Angle Limit: The angle within which if the minimum width is not detected,
an error is returned as the status of the result.
Parameters are set using LOAD_CMD (40).
Holdoff Angle 0
Algorithm 0
Angle Limit 0
Holdoff Angle 1
Algorithm 1
Angle Limit 1
*1: Setting for the result 2 and result 2 shall not be
changed from the default setting.