3.2 Board Carriage ① IN motor Carriage motor for IN bu ffer (An induction motor) ② CENT motor Carriage motor for centering station (A stepping motor) ③ OUT motor Carriage motor for OUT bu ffer (An induction motor) ④ Stop…

100%1 / 228
YR origin deceleration sensor ON?
Z axis faulty?
Move away from YR origin sensor.
Lock YL axes.
Move by 1 step until YR origin
sensor turns on.
Initialization of work data
Considered to be normal
NO
YES
2/21/2
Considered to be faulty
End
- 48 -
3.2 Board Carriage
IN motor
Carriage motor for IN buffer (An induction motor)
CENT motor
Carriage motor for centering station (A stepping motor)
OUT motor
Carriage motor for OUT buffer (An induction motor)
Stopper
Centering station board stopper
Backup
Interlocked operation among fiducial pin, side cramp and backup pin
Shape cramp
Interlocked operation between Y cramp y and X cramp u
IN sensor
Carry in detection sensor for IN buffer
WAIT sensor
Standby position detection sensor for IN buffer
STOP sensor
Centering station stop sensor (Also functions as deceleration sensor.)
C.OUT sensor
Centering station carry out sensor
OUT sensor
Carry out detection sensor for OUT buffer
BU UP sensor
Backup table UP sensor
BU DN sensor
Backup table DOWN sensor
- 49 -
- 50 -
3.2.1 Errors and effects
Errors are detected and displayed when the board is carried in or carried out.
If an error occurs, immediately turn off the output of the drive system which is
the cause of the error. However, the backup in production will not be reset.
Error type Details
IN buffer error
IN motor continuously turns for 10 seconds or more.
IN sensor turns on for 0.5 second or more when WAIT sensor is on.
IN sensor and WAIT sensor turn on simultaneously when IN motor is rotating.
Centering station
error
CENT motor continuously turns for 10 seconds or more.
STOP sensor turns from off to on when C.OUT sensor is on.
OUT buffer error
OUT motor continuously turns for 10 seconds or more.
C.OUT sensor and OUT sensor turn on simultaneously.
Backup error
UP sensor does not turn on for 2 seconds or more after backup is on.
DN sensor does not turn off for 2 seconds or more after backup is on.
DN sensor does not turn on for 2 seconds or more after backup is off.
UP sensor does not turn off for 2 seconds or more after backup is off.
3.2.2 Timing chart
The following pages shows the timing chart of carriage operation in idle mode
and during production.