- 6 5 - wZDownWait wZUpWait wTimeout wCloseTime lAccelSection lScanFromTip lRetryPitch lRetry; wBlowOn wRsv1 wRsv2 wRsv3 wPickVac wPlaceVac wBlowOff wVacOff wVcsStd wVcs03 wBocMark wIcMark wLaSweep wLaOnce wZPlace wScrap…

100%1 / 228
- 64 -
Variables
Waiting time for dumping at other positions
Mark position
VCS position
ATC position
Applied position
MTC position
Verify position
Virtual position 0
Virtual position 1
Position where dumping duration is ignored
Cover open
Ditto
On-the-fly operation
JOG start operation (High speed)
JOG start operation (Low speed)
JOG stop operation
STEP operation
JOG start operation when origin return
(- direction)
JOG stop operation when origin return
(- direction)
JOG start operation when origin return
(+ direction)
JOG stop operation when origin return
(+ direction)
STEP operation when origin return
PTP operation When L.L.L execution
Reserved
PTP operation when cover open
Preload start time after movement of Z axis in
upward direction
Part type 0 to 9
No part
Cover open
Nozzle
Nozzle YES/NO check threshold
Part pick YES/NO check threshold when picked
Waiting time for vacuum pressure goes high
when part pick
Waiting time for vacuum off when part mount
Part YES/NO check threshold before mount
Reserved
Simultaneous pick range
Push in amount when mounted
Push in amount when picked
Unit
msec
msec
msec
msec
msec
msec
msec
msec
msec
msec
msec
msec
msec
%
msec
msec
%
0.1mm
0.1mm
Length
20
2
2
2
2
2
2
2
2
2
2
666
740
740
60
4
1
1
2
4
4
4
4
4
4
4
4
4
4
16
4
24
20
2
2
140
1
1
1
1
1
1
8
2
2
Data type
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
BYTE
BYTE
WORD
WORD
WORD
WORD
BYTE
BYTE
BYTE
BYTE
BYTE
BYTE
tPos
WORD
WORD
Description
wPreLoadStarTime [12]
stNozzle [100]
wPushInPlace
wPushInPick
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
byVel
byAcl
wDmpg
[0] – [9]
[10]
[11]
H [1] – H [9]
Medium speed (
The same structure as for high speed
)
Low speed (
The same structure as for high speed
)
stEtcSp [15]
stCover (tXYEtcSp)
byNozzleThreshold
byCmpntThreshold
byTimeout
byPlaceVacuumWait
byCmpntThreshold2
byReserve
stPick
wElsDmpg
Ditto
[0]
[1]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
[10]
[11] – [14]
- 65 -
wZDownWait
wZUpWait
wTimeout
wCloseTime
lAccelSection
lScanFromTip
lRetryPitch
lRetry;
wBlowOn
wRsv1
wRsv2
wRsv3
wPickVac
wPlaceVac
wBlowOff
wVacOff
wVcsStd
wVcs03
wBocMark
wIcMark
wLaSweep
wLaOnce
wZPlace
wScrapBlow
wZGainBlow
wBadMark
wRsv [4]
Variables
ATC unit 1
ATC unit 2 (Not used)
Waiting time for Z downward movement
Time from plate sensor ON to Z upward movement
Timeout duration for plate open/close
Plate closing operation completion time
Laser read locator control
Distance for acceleration when detection
Scanning position from the pin tip
The amount of increase in scanning position
from the pin end when coplanarity retry
High limit of the number of retries per side when
coplanarity scanning fails
Waiting time per part type
Blow start time before mount Z downward
movement completion
Reserved
Reserved
Reserved
Waiting time per part type
Waiting time for part vacuum
Waiting time for mount vacuum
Blow stop time before lifting up for mount
Vacuum stop time before mount Z downward
movement completion
Waiting times
Time until part vision after Z axis moves to
standard VCS
Time until part vision after Z axis moves to 0.3 mm VCS
Time until mark vision after move to BOC mark
Time until mark vision after move to IC mark
Time until SWEEP start after XY axes movement start
Time until ONCE start after XY axes movement start
Time for Z axis downwards movement after XY
axes movement finish
Blow time when part discarded
Z axis gain low time
Time for mark read after move to bad mark
Reserved
Chip rise YES/NO check height computation coefficient
Classification board carriage specification
Number of pick position automatic adjustment
Different part check coefficient (To the ratio depth/width)
Different part check coefficient (Chip, Melf, SOT)
Different part check coefficient (Other than the above)
Stain check level (Default 80)
Stain check CCD count (Default 1)
Spare 1 for relativity check
Spare 2 for relativity check
Unit
msec
msec
msec
msec
0.1µ
0.1µ
0.1µ
Times
Length
8
8
2
2
2
2
16
4
4
4
4
400
2
2
2
2
400
2
2
2
2
28
2
2
2
2
2
2
2
2
2
2
8
2
2
2
2
2
2
2
2
2
2
Data type
WORD
WORD
WORD
WORD
LONG
LONG
LONG
LONG
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
WORD
Description
stAtc [0]
stAtc [1]
stL3
stCmpnt2 [50]
stCmpnt [50]
stWaitTime
wChipCoef
wConvyerSpec
wPickAdjustTime
wDiffCompoRatio
wDiffCompoChip
wDiffCompoOther
wLasChkLevel
wLasChkCount
wLasChkRsv1
wLasChkRsv2
- 66 -
lX
lY
lX
lY
lX
lY
lDarkLevel
lMinPixel
lMinLowPass
lBackground
lMaxLowPass
lMaxPixel
lRmsMidFreq
lMaxMidFreq
lRmsHiFreq
lAbsHiFreq
lEvenOdd
lNonFlat
Variables
Range of X direction simultaneous nozzle
replacement
Range of Y direction simultaneous nozzle
replacement
Field to field distance when X direction split
recognition (For standard VCS)
Field to field distance when Y direction split
recognition (For standard VCS)
Field to field distance when X direction split
recognition (For optional VCS)
Field to field distance when Y direction split
recognition (For optional VCS)
Dark Level
Min raw pixel value
Min low-pass filtered value
Median background level
Max low-pass filtered value
Max raw pixel value
RMS median filtered noise
Max median filtered error
RMS high frequency noise
Absolute high frequency noise
Even-odd pixel value mismatch
RMS low frequency noise
Reserved
UnitLength
8
4
4
8
4
4
8
4
4
96
4
4
4
4
4
4
4
4
4
4
4
4
60
Data type
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
LONG
WORD
Description
stNzlChgRange
stVcsStdDist
stVcsOptDist
stLasChkLimit [2]
wRsv [30]